AIR FOR COMBUSTION

AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see option 3, Figure 4). Follow the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power

Ventilation

 

Grills

 

Into Adjoining

Or

Room,

Remove

Option 1

Door into

 

 

Adjoining

 

Room,

 

Option

 

3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install firebox. Follow all local codes.

12"

Figure 4 - Ventilation Air from Inside

Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 5 - Ventilation Air from Outdoors

WARNING: Never install the firebox

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the firebox

in high traffic areas

in windy or drafty areas

WARNING: Never install the firebox

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the firebox

in high traffic areas

in windy or drafty areas

8

www.desatech.com

105604-01H

Page 8
Image 8
Vanguard Heating FB32CA Installation, Ventilation AIR, Ventilation Air From Inside Building, Ventilation Air From Outdoors

NLFB32NC, NLFB32C, FB32CA, FB32NCA specifications

The Vanguard Heating NLFB32NC, FB32NCA, FB32CA, and NLFB32C are modern, innovative heating systems crafted to meet the demands of contemporary living spaces. These models emphasize efficiency, reliability, and advanced technology, making them a popular choice for both residential and commercial applications.

One of the standout features of the Vanguard Heating line is its energy efficiency. Designed with cutting-edge technology, these heating units boast optimized heating performance while minimizing energy consumption. With a high energy efficiency rating, they help users reduce their carbon footprint and lower utility bills, providing a substantial return on investment over the years.

These models incorporate advanced heating technologies, including variable speed fans, which adjust according to the heating needs of the space. This feature not only enhances comfort by maintaining a consistent temperature but also reduces noise levels, allowing for a peaceful environment. The intuitive control systems enable users to easily adjust settings, ensuring that their heating preferences are met at all times.

Constructed with durable materials, the Vanguard Heating models are designed to withstand the rigors of daily use. Their robust build quality ensures longevity and reduces the need for frequent maintenance. Additionally, the compact design of these systems allows for flexible installation, making them suitable for a variety of settings, whether in tight spaces or larger areas.

Moreover, the NLFB32NC and its counterparts are equipped with safety features that prioritize user protection. Overheat protection and automatic shut-off mechanisms are standard, ensuring that the units operate safely and efficiently. These heating systems also come with easy-to-read digital displays, enabling users to monitor performance and troubleshoot any issues quickly.

The Vanguard Heating series is also designed with environmental considerations in mind. They comply with stringent environmental standards, contributing to a greener future. The use of sustainable materials in production further reflects Vanguard's commitment to eco-friendly practices.

In summary, the Vanguard Heating NLFB32NC, FB32NCA, FB32CA, and NLFB32C offer a comprehensive heating solution characterized by energy efficiency, advanced heating technologies, durability, and safety features. Their innovative designs cater to a wide range of heating needs, making them an excellent choice for anyone seeking reliable, high-performance heating solutions. By choosing Vanguard Heating, users benefit from enhanced comfort, cost savings, and a reduced environmental impact.