OWNER’S MANUAL

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 27) or replace burner

 

 

 

 

orifice

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

Thermopile leads disconnected or im-

3.

Reconnect leads (see Wiring Diagram,

 

 

properly connected

 

page 31)

 

4.

Thermopile is defective

4.

Replace thermopile

 

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP or natural gas

 

 

 

 

company

 

2.

Burner porting or orifice clogged

2.

Clean burner (see Cleaning and Main-

 

 

 

 

tenance, page 27) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 27) or replace burner

 

 

 

 

orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing

1.Problem will stop after a few hours of operation

Burner system produces a whistling noise

1.

Turning gas control knob to HI position

1.

Turn gas control knob to LO position and

when burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane/LP or natural gas company

 

3.

Dirty or partially clogged burner orifice

3.

Clean burner (see Cleaning and

 

 

 

 

Maintenance, page 27) or replace burner

 

 

 

 

orifice

 

 

 

 

 

Glass soots

1.

Flame impingement on logs

1.

Adjust the log set so that the flame does

 

 

 

 

not excessively impinge on it

 

2.

Debris around burner air mixer

2.

Inspect the opening at the base of the

 

 

 

 

burner to see that it is NOT packed with

 

 

 

 

any type of material

 

 

 

 

 

Burner system produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common. If noise is excessive, contact qualified service person

Remote does not function

1. Battery is not installed or battery power

 

is low

1.Replace 9-volt batteries in receiver and remote control

www.desatech.com

Continued

105499

29

Page 29
Image 29
Vanguard Heating SDVBP(A), SDVBN(A) manual Observed Problem Possible Cause Remedy

SDVBP(A), SDVBN(A) specifications

Vanguard Heating SDVBN(A) and SDVBP(A) are innovative heating solutions designed for residential and commercial applications, aiming to deliver unparalleled efficiency and comfort. These models showcase advanced technologies tailored to meet modern heating demands while ensuring minimal environmental impact.

One of the standout features of the Vanguard Heating SDVBN(A) and SDVBP(A) is their highly efficient heating performance. Operating with an Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%, these models convert a significant portion of fuel into heat, minimizing energy waste and lowering utility costs. This efficiency translates to substantial savings for homeowners and businesses alike, making them an economically sound choice in the long run.

The SDVBN(A) and SDVBP(A) are equipped with variable-speed blower motors, allowing for precise control of airflow. This technology not only enhances comfort by maintaining consistent temperature levels throughout spaces but also contributes to reduced noise levels during operation. The quiet performance of these units is particularly appealing for residential settings, such as bedrooms and living areas.

In terms of versatility, Vanguard offers multiple configurations, allowing installers to tailor the heating system to specific requirements. Whether it’s a large open plan or a more segmented layout, the adjustable airflow and zoned heating capabilities ensure that every corner of the space is adequately warmed.

Another notable characteristic is the integrated smart technology. Both models come with advanced control systems that can be easily connected to compatible smart thermostats. This allows users to monitor and adjust heating settings remotely, providing added convenience and optimizing energy usage according to individual schedules.

Moreover, the SDVBN(A) and SDVBP(A) feature robust construction designed for durability. With high-quality materials and components, these units can withstand the rigors of daily use, ensuring reliable performance throughout their lifespan. Regular maintenance is simplified due to accessible design, empowering users or service technicians to conduct routine checks and repairs with ease.

Vanguard Heating has also incorporated safety features, including built-in sensors that monitor system performance and automatically shut down the unit in case of any malfunctions. This proactive approach provides peace of mind, knowing that the heating system is both efficient and safe.

In summary, Vanguard Heating SDVBN(A) and SDVBP(A) models embody cutting-edge technology, efficiency, and reliability in home and commercial heating solutions. Their ability to deliver comfortable, quiet, and economical heating while prioritizing safety and ease of maintenance makes them an excellent choice for any heating application.