Vanguard Heating SDVBP(A) Installing Optional Blower Accessory, Installing GA3700/DA3610T Blowers

Models: SDVBP(A) SDVBN(A)

1 38
Download 38 pages 60.83 Kb
Page 7
Image 7

OWNER’S MANUAL

CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLY

Continued

INSTALLING OPTIONAL BLOWER ACCESSORY

NOTICE: If installing blower in an existing stove burner system with gas connections, shut off gas supply and disconnect stove burner system from gas supply. Contact a qualified service per- son to do this.

Attaching Thermal Switch to DA3610T Thermostatically- Controlled Blower

When installing the DA3610T thermostati- cally-controlled blower accessory, you must first secure the thermal switch to the blower.

1.

Remove the two hex head screws on the

 

blower assembly as shown in Figure 15.

2.

Place the green wire between the bot-

 

tom hole on the thermal switch bracket

 

and the bottom hole on the blower as-

 

sembly. Insert one of the hex screws

 

into all three pieces and tighten.

3.

Insert the top screw through the ther-

Installing GA3700/DA3610T Blowers

1.Align the holes in the top mounting tabs of blower with holes in wall of rear cover (see Figure 16). Using the 4 screws provided, mount blower and tighten screws securely.

Note: For DA3610T, make sure the thermal switch has been properly in- stalled to fit against the back of the burner system.

2.Make sure all wire connections to ter- minals on blower motor (and thermal switch where applicable) are securely attached and that the screw retaining the green ground wire is tight.

3.Place speed control on left inside of rear cover and push the plastic control shaft through opening (see Figure 16).

4.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until tight against the side of rear cover. Place control knob provided onto shaft (see Figure 16).

5.Plug in blower power cord.

6.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign ob-

jects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclock- wise before continuing.

WARNING: Never touch the blower wheel while in operation.

7.Peel off the backing paper and stick the supplied wiring diagram decal on the inside of rear cover on right side oppo- site control.

WARNING: Failure to position the parts in accordance with sup- plied diagrams or failure to use only parts specifically approved with this stove and burner sys- tem may result in damage or per- sonal injury.

8.Connect or reconnect gas supply to stove/burner system per Connecting Stove/Burner System to Gas Supply on page 19 of this manual.

WARNING: A qualified ser- vice person must connect burner system to gas supply. Follow all local codes.

 

mal switch bracket and into the blower

 

assembly. Tighten screw.

4.

Connect the blue wire on the blower

 

assembly to the right side of the ther-

 

mal switch.

5.

Connect the black wire to the left side

 

of the thermal switch.

Black

White Wire

Wire

Blower

 

 

Assembly

Thermal

Green

Switch

Wire

with

Blue Wire

Bracket

Hex Head

 

 

Screws

Figure 15 - Attaching Thermal Switch to DA3610T Thermostatically-Controlled Blower Accessory

Blower

Speed Control

Control Knob

Control Shaft

Lock Nut

 

Power Cord

Mounting Screws (Included in Hardware Pack)

Black

Wiring

White Wire

Wire

Diagram

 

Decal

 

Green

Rear Cover

Blue

Blower

Ground

Wire

Wire

 

 

 

Figure 16 - Installing Optional Blower Accessory (Thermostat Model DA3610T Shown)

Continued

105499

7

Page 7
Image 7
Vanguard Heating SDVBP(A), SDVBN(A) manual Installing Optional Blower Accessory, Installing GA3700/DA3610T Blowers

SDVBP(A), SDVBN(A) specifications

Vanguard Heating SDVBN(A) and SDVBP(A) are innovative heating solutions designed for residential and commercial applications, aiming to deliver unparalleled efficiency and comfort. These models showcase advanced technologies tailored to meet modern heating demands while ensuring minimal environmental impact.

One of the standout features of the Vanguard Heating SDVBN(A) and SDVBP(A) is their highly efficient heating performance. Operating with an Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%, these models convert a significant portion of fuel into heat, minimizing energy waste and lowering utility costs. This efficiency translates to substantial savings for homeowners and businesses alike, making them an economically sound choice in the long run.

The SDVBN(A) and SDVBP(A) are equipped with variable-speed blower motors, allowing for precise control of airflow. This technology not only enhances comfort by maintaining consistent temperature levels throughout spaces but also contributes to reduced noise levels during operation. The quiet performance of these units is particularly appealing for residential settings, such as bedrooms and living areas.

In terms of versatility, Vanguard offers multiple configurations, allowing installers to tailor the heating system to specific requirements. Whether it’s a large open plan or a more segmented layout, the adjustable airflow and zoned heating capabilities ensure that every corner of the space is adequately warmed.

Another notable characteristic is the integrated smart technology. Both models come with advanced control systems that can be easily connected to compatible smart thermostats. This allows users to monitor and adjust heating settings remotely, providing added convenience and optimizing energy usage according to individual schedules.

Moreover, the SDVBN(A) and SDVBP(A) feature robust construction designed for durability. With high-quality materials and components, these units can withstand the rigors of daily use, ensuring reliable performance throughout their lifespan. Regular maintenance is simplified due to accessible design, empowering users or service technicians to conduct routine checks and repairs with ease.

Vanguard Heating has also incorporated safety features, including built-in sensors that monitor system performance and automatically shut down the unit in case of any malfunctions. This proactive approach provides peace of mind, knowing that the heating system is both efficient and safe.

In summary, Vanguard Heating SDVBN(A) and SDVBP(A) models embody cutting-edge technology, efficiency, and reliability in home and commercial heating solutions. Their ability to deliver comfortable, quiet, and economical heating while prioritizing safety and ease of maintenance makes them an excellent choice for any heating application.