® SDVBN(A) AND SDVBP(A)
CAST IRON STOVE AND BURNER SYSTEM
PRE-INSTALLATION PREPARATION
WARNING: A qualified ser- vice person must install stove and burner system. Follow all lo- cal codes.
CAUTION: This stove creates warm air currents. These currents move heat to wall surfaces next to stove. Installing stove next to vinyl or cloth wall coverings or operating stove where impurities (such as tobacco smoke, aro- matic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.
LOCATION AND SPACE REQUIREMENTS
Determine the safest and most efficient loca- tion for your Vanguard cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows, or doors. Figure 2 shows some common loca- tions. Read all venting information in this manual. Be aware of all restrictions and pre- cautions before deciding the exact location for your stove.
When deciding the location of your stove, follow these rules:
On Wall with
Horizontal Termination
On Wall with Vertical Corner Installation Termination Through
Ceiling
Figure 2 - Common Stove Locations
Ceiling
42"
36" |
|
|
|
|
| 4" |
|
|
|
|
| ||
from |
|
|
|
|
|
|
Front |
|
|
|
|
| |
|
|
|
|
|
Back
Wall
Floor
Must contain a minimum
of 1" clearance to combustibles
29"
1.Do not connect this stove and burner system to a chimney flue serving a separate
2.Due to high temperatures, do not lo- cate this stove in high traffic areas or near furniture or draperies.
3.Proper clearances must be maintained, see Figure 3 and Figure 4 on page 5.
4.This stove is a freestanding unit de- signed to set directly on the floor. If your stove is to be installed directly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel ex- tending the full width and depth of the stove. See Figure 5, page 5.
4"
6"
Front
Figure 3 - Clearances for Standard Installation
4 | 105499 |