The Chimney System
Creosote
Your Intrepid
When wood is burned slowly, it produces tar, organic vapors and moisture that combine to form creosote. The creosote vapors condense in the relatively cool chimney flue. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire within the flue system that can dam- age the chimney and overheat adjacent combustible material.
If you do have a chimney fire, act promptly to:
•Close the damper and thermostat lever.
•Get everyone out of the house.
•Call the Fire Department.
You should inspect the system every two weeks during the heating season as part of a regular maintenance schedule. To inspect the chimney, let the stove cool completely. Then, using a mirror and a strong light, sight up through the flue collar into the chimney flue. If it is not possible to inspect the flue system in this fashion the stove must be disconnected to provide better view- ing access.
If a significant layer of creosote has accumulated - 1/8” (3mm) or more - remove it to reduce the risk of a chim- ney fire.
Clean the chimney using a brush the same size and shape as the flue liner. Flexible fiberglass rods are used to run the brush up and down the liner, causing any deposits to fall to the bottom of the chimney where they can be removed through the clean out door.
The chimney connector should be cleaned by discon- necting the sections, taking them outside, and removing any deposits with a stiff wire brush. Reinstall the con- nector sections after cleaning, being sure to secure the individual sections with sheet metal screws.
If you cannot inspect or clean the chimney yourself, contact your local Vermont Casings, Majestic Prod- ucts authorized dealer or hire a professional chimney sweep.
Vermont Castings Intrepid
Annual Maintenance
Every spring, at the end of the heating season, perform a thorough cleaning, inspection and repair. The stove and chimney system should be inspected and main- tained by a qualified engineer.
•Thoroughly clean the chimney and chimney con- nector.
•Inspect the chimney for damage and deteriora- tion. Replace weak sections of prefabricated chimney. Have a mason make repairs to a ma- sonry chimney.
•Inspect the chimney connector and replace any damaged sections.
•Check gasketing for wear or compression, and replace if necessary. A ‘paper test’ will guide you on this. Close and lock the door or damper on a slip of paper and then try to pull the paper out. If the paper pulls out with little or no resistance, the gasket is not snug enough at that spot. If adjust- ing the damper or latch does not result in a seal that makes it hard to pull the paper out, replace the gasketing.
•Check door and damper handles for tightness. Adjust if needed.
•Check heat shield screws. Tighten as necessary.
•Clean dust from the inner sides of bottom, rear and connector heat shields.
•Remove ashes from the ash pan and replace with moisture absorbing material (such as cat litter) to keep the stove interior dry. Close the stove door to keep cats from using the litter.
•Touch up the paint on black stoves.
Please record the following information
for future reference.
Stove Serial No. __________________________
Dealer _________________________________
________________________________________
________________________________________
Phone __________________________________
Date Purchased __________________________
Installer ___________________________
_______________________________________
_______________________________________
Phone _______________________________
Date Installed _________________________
2000970 | 21 |