14
Intrepid II Woodburning Stove
2000966
Intrepid II Clearance Chart
See Pages 15 and 16 for illustrations of these clearances.
* Clearances with double-wall connectors and protected surfaces have not been tested for the Intrepid II.
1. Shielding for a top exit stove must include the stove rear heat shield insert to protect the area behind the flue collar.
2. Chimney connector heat shields, in an installation that goes through a combustible ceiling, must extend to 1” (25 mm) below
the ceiling heat shield, which is 22” (559 mm) in diameter. The ceiling heat shield should be 24 gauge or heavier sheet metal,
centered on the chimney connector, and mounted on noncombustible spacers.
3. Rear exit—horizontal from flue collar directly back through wall.
4. The ceiling heat shield required when chimney connector shields are used should meet the wall protector. This will require trim-
ming the ceiling shield along the line of intersection with the wall protector.
5. In top exit installations, this clearance requires the use of the rear heat shield with the shield insert installed.
Stove Installed Stove in Stove Installed Stove in
Parallel to Wall Corner Paralle to Wall Corner
Side Rear Corners Side Rear Corners
No stove heat shields (A) 24” (B) 30” (C) 20” (D) 12” (E) 16” (F) 10”
(610 mm) (762 mm) (508 mm) (305 mm) (406 mm) (254 mm)
Top exit, rear stove h.s.,
single-wall chimney (G) 24” (H) 16” (I) 12” (J) 12” (K) 9” (L) 10”
connector with connector (610 mm) (406 mm) (305 mm) (305 mm) (229 mm) (254 mm)
heat shields1,2
Rear exit, rear stove (M) 24” (N) 14” n/a (P) 12” (Q) 9” n/a
heat shield3 (610 mm) (356 mm) (305 mm) (229 mm)
Top exit, rear stove h.s., (G) 24” (H) 16” (I) 12” *
double-wall (610 mm) 406 mm) (305 mm)
chimney connector5
Single-wall chimney
connector, no 26” (660 mm) 12” (305 mm)
connector heat shields
Single-wall chimney
connector, with 10” (254 mm) 5” (127 mm)4
connector heat shields
Double-wall 12” (305 mm) *
connector5
All Installations 48” (1219 mm)
Unprotected Surfaces Protected SurfacesStove Clearance

Chimney Connector Clearance

Front Clearance to Combustibles