Intrepid II Woodburning Stove

Fireplace Chimney Installations -

Through a Fireplace

If your fireplace height is at least 25” (635mm), you may install an Intrepid II with standard legs through the fireplace opening using a “positive connection” kit available from your local dealer. These positive connec- tion kits ensure a tight fit between the stove flue collar and the chimney flue. (Fig. 8) Fireplace installations, whether connected to the flue above or through the fireplace opening, have special clearance requirements to adjacent trim and the mantel. You’ll find the required clearances for the Intrepid II fireplace installations on Page 14.

Floor protection requirements also apply to fireplace installations. Floor protection information is on Page 9.

Flexible Connector

Mantel Shield

Fireplace Adaptor Kit

ST245

Fig. 8 Chimney connector enters chimney through the fire- place opening.

Wall Pass-Throughs

Whenever possible, design your installation so the con- nector does not pass through a combustible wall. If you are considering a wall pass-through in your installation, check with your building inspector before you begin.

Also, check with the chimney connector manufacturer for any specific requirements.

Accessories are available for use as wall pass- throughs. If using one of these, make sure it has been tested and listed for use as a wall pass-through.

In the United States, the National Fire Protection As- sociation (NFPA) has established guidelines for passing chimney connectors through combustible walls. Many building code inspectors follow these guidelines when approving installations.

Figure 9 shows one NFPA-recommended method. All combustible material in the wall is cut away from the single-wall connector to provide the required 12” (305mm) clearance. Any material used to close up the opening must be noncombustible.

Three other methods are also recommended by NFPA:

Using a section of double-wall chimney with a 9” (230mm) clearance to combustibles.

Placing a section of chimney connector inside a ven- tilated thimble, which in turn is separated from combus- tibles by 6” (150mm) of fiberglass insulating material.

Placing a section of chimney connector inside a section of 9” (230mm) diameter, solid-insulated, factory- built chimney, with 2” (50mm) of air space between the chimney section and combustibles.

Wall Stud

Chimney

Connector

I

 

T

N

TR

 

EPI

 

 

D II

 

12” of Noncombustible Material

Floor

 

Protection

ST493a

 

Fig. 9 An approved wall pass-through for the United States.

In Canada, The Canadian Standards Association has established installation guidelines. The following il- lustration shows one method, in which all combustible material in the wall is cut away to provide the required 18” (460 mm) clearance for the connector. The resulting space must remain empty. A flush-mounted sheet metal cover may be used on one side only. If covers must be used on both sides, each cover must be mounted on noncombustible spacers at least 1” (25 mm) clear of the wall.

8

2000966

Page 8
Image 8
Vermont Casting 1990 installation instructions Fireplace Chimney Installations Through a Fireplace, Wall Pass-Throughs

1990 specifications

Vermont Casting, founded in 1975, is renowned for its commitment to crafting high-quality cast iron wood stoves and heaters that merge efficiency with timeless design. By 1990, Vermont Casting had established itself as a leader in the industry, celebrated for its innovative approach to heating solutions and commitment to sustainability.

The 1990 models reflected an impressive evolution in technology and aesthetics. One of the standout features of Vermont Casting stoves was their utilization of advanced air control systems. This technology allowed users to regulate the burn speed and heat output effectively, making it easier to maintain consistent warmth in the home while optimizing fuel efficiency. The stoves featured an adjustable air inlet that provided users with the power to control combustion according to their needs.

In terms of design, Vermont Casting stoves were characterized by their iconic, rustic appearance, often featuring a choice of colors and finishes that allowed them to blend seamlessly into a variety of home aesthetics. The deep, rich finishes of the cast iron, coupled with elegant detailing, made each unit not only a heating appliance but also a centerpiece in living spaces. This commitment to aesthetics extended to the variety of designs available, including both traditional and modern styles, catering to diverse consumer preferences.

Vermont Casting also prioritized safety in their 1990 models. Many stoves were equipped with features such as double doors with glass panels, allowing users to enjoy the beauty of the flames while minimizing the risk of accidental burns. Some models incorporated heat shields that protected surrounding walls and furniture from excessive heat, further enhancing safety at home.

Durability was another hallmark of Vermont Casting’s reputation. The use of high-quality cast iron meant that these stoves were built to withstand years of use, often becoming familial heirlooms passed down through generations. In addition to resilience, cast iron was known for its ability to retain heat even after the fire had gone out, providing lingering warmth long into the night.

Overall, Vermont Casting in 1990 represented a harmonious blend of timeless design, advanced functionality, and a commitment to sustainability. Their stoves were not merely heating appliances but symbols of a lifestyle choice that emphasized quality, elegance, and environmental responsibility, making them a preferred choice for homeowners seeking both reliability and beauty in home heating solutions.