Encore Clearance Chart

For use with either 6” or 8” flue collar/chimney connection

 

Unprotected Surfaces

Protected Surfaces

 

 

 

 

 

 

 

 

 

 

 

 

Stove Clearance

 

 

 

 

 

 

 

 

 

 

 

Stove Installed

Stove

Stove Installed

Stove

 

Parallel to Corner

in Corner

Parallel to Wall

in Corner

 

 

 

 

 

 

 

 

 

Side

Rear

Corners

Side

 

Rear

Corners

No stove heat shields

(A) 24”

(B) 31”

(C) 24”

(D) 8”

 

(E) 15”

(F) 8”

 

(610 mm)

(787 mm)

(610 mm)

(203 mm)

 

(380 mm)

(203 mm)

 

 

 

 

 

 

 

 

Top Exit, rear stove h.s.,

(G) 24”

(H) 19”

(I) 17”

(J) 8”

 

(K) 11”

(L) 7”

single-wall chimney con-

(610 mm)

(483 mm)

(432 mm)

(203 mm)

 

(280 mm)

(178 mm)

nector heat shields1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear Exit, rear stove

(M) 24”

(N) 19”

N/A

(P) 8”

 

(Q) 11”

N/A

heat shield only

(610 mm)

(483 mm)

 

(203 mm)

 

(280 mm)

 

 

 

 

 

 

 

 

 

 

 

Top Exit, rear stove h.s.,

(G) 24”

(H) 19”

(I) 24”

 

 

 

 

 

double-wall chimney

(610 mm)

(483 mm)

(610 mm)

 

 

*

 

 

connector3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney Connector Clearance

 

 

 

 

 

 

 

 

 

 

 

Single-wall connector,

24”

(610 mm)

 

 

8”

(203 mm)

 

 

No chimney connector

 

 

 

 

 

 

 

 

heat shields

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-wall connector,

12”

(305 mm)

 

 

4”

(102 mm)2

 

 

Chimney connector heat

 

 

 

 

 

 

 

 

shields installed

 

 

 

 

 

 

 

 

Double-wall connector3

12”

(305 mm)

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

Clearance to Combustibles in Front of Stove

 

 

 

 

 

 

 

 

 

 

 

 

All Installations

(S) 48” (1219 mm)

 

 

 

 

 

 

 

 

 

 

 

* Clearances with double-wall connectors and protected surfaces have not been tested for the Encore.

1.A ceiling heat shield, 24” (610 mm) in diameter and suspended 1” (25 mm) from the ceiling, must surround the chimney connector in installations in which the chimney connector penetrates the ceiling. The chimney connector shield extends only to 28” (710 mm) above the flue collar.

2.The ceiling heat shield required when the chimney connector shields are used should meet the wall protector. This will require trimming the ceiling shield along the line of intersection with the wall protector.

3.In top-exit installations, this clearance requires the use of a rear stove heat shield with the flue collar insert installed.