FP1430
Fig. 8 Alternate switch location.
Optional Top Vent Application
This appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent con- figuration, the appliance can be converted by following the steps below.
When removing and refitting the plates and adapter, be sure the associated gasket is undamaged and refitted as required.
1.Remove the ten (10) screws securing the outer col- lar adapter to the fireplace body. (Fig. 9)
2.Set the collar aside, complete with the gasket.
NOTE: Do not damage the gasket, as the adapter and gasket must be refitted.
3.Remove the insulation material (exposed in Step 2) from the top of the unit. (Fig. 10) This material can be discarded; however, if the unit is converted back to
NOTE: When converting appliance to top vent, ensure the insulation material referred to in step 3 is completely removed.
4.Remove the 4 screws securing the flue cover plate to the top of the intake box and remove the cover and gasket. (Fig. 11)
5.Remove 4 screws securing the flue pipe to back of the intake box and remove pipe and gasket. (Fig. 11)
6.Secure the plate and gasket removed in step 4 over the flue opening in the back of the intake box. En- sure the gasket is in place and undamaged.
7.Install the flue pipe and gasket removed in step 5 over the flue opening in the top of the intake box.
8.Refit the outer collar adapter and gasket to the unit with the round collar on the top. Secure the adapter with the 10 screws removed in step 1.
10006326
360DVS Series Direct Vent Fireplaces
Remove These Screws
Remove
These
Screws
Outer Collar Adapter
FP1431
Fig. 9 Remove screws from outer collar adapter.
Insulation Pad (Must be removed)
Flue
Pipe
| FP1432 |
Fig. 10 | Remove flue cover and pipe. |
| Flue Cover |
| Plate |
| Flue |
| Pipe |
FP1433 |
|
Fig. 11 | Flue pipe removal. |
| 11 |