Vermont Casting 360DVS2, 360DVSR Framing & Finishing, Final Finishing, Gas Specifications, Natural

Models: 360DVS3 360DVSL 360DVSR 360DVS2

1 31
Download 31 pages 19.59 Kb
Page 8
Image 8
Framing & Finishing

Framing & Finishing

1.Choose the unit location.

2.Place the unit into position and secure it to the floor with 1¹⁄₂” (38mm) screws or nails. Holes to secure the unit to the floor are located behind the access door grille on the left and right sides of the unit.

3.Frame in the fireplace with a header across the top. It is important to allow for the finished wall face when setting the depth of the frame.

4.Drywall (sheetrock) or wood material may be placed with a zero clearance to the top edges of the appli- ance when finishing walls above sides of the appli- ance with glass windows. NOTE: Attach wall finish- ing to constructed frame, not the appliance.

5.On 360DVSL and 360DVSR, drywall, wood, or wood molding may be placed with zero clearance to the rear wall of the unit, along the vertical edge formed by the standoffs, to intersection of the rear wall, to the side wall having the small glass window. NOTE:

Attach wall finishing to constructed frame, not the appliance.

Final Finishing

Noncombustible materials such as brick or tile may be extended over the edges of the face of the appliance. DO NOT cover any vent or grille panels.

If a Trim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the appliance.

Gas Specifications

 

 

 

 

 

 

 

 

Max.

Max.

 

 

 

Input

Input

Model

Fuel

Gas Control

BTU/h

BTU/h

360DVS2RN

Nat

Millivolt

38,000

26,600

360DVS2RP

Prop

Millivolt

38,000

28,500

360DVS2EN

Nat

24V Hi/Lo

38,000

26,600

360DVS2EP

Prop

24V Hi/Lo

38,000

28,500

360DVS3RN

Nat

Millivolt

38,000

26,600

360DVS3RP

Prop

Millivolt

38,000

28,500

360DVS3EN

Nat

24V Hi/Lo

38,000

26,600

360DVS3EP

Prop

24V Hi/Lo

38,000

28,500

360DVSLRN

Nat

Millivolt

38,000

26,600

360DVSLRP

Prop

Millivolt

38,000

28,500

360DVSLEN

Nat

24V Hi/Lo

38,000

26,600

360DVSLEP

Prop

24V Hi/Lo

38,000

28,500

360DVSRRN

Nat

Millivolt

38,000

26,600

360DVSRRP

Prop

Millivolt

38,000

28,500

360DVSREN

Nat

24V Hi/Lo

38,000

26,600

360DVSREP

Prop

24V Hi/Lo

38,000

28,500

360DVS Series Direct Vent Fireplaces

Gas Inlet & Manifold Pressures

 

 

 

 

Natural

LP (Propane)

Inlet Minimum

4.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

 

 

 

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.

For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations above 4,500 feet (1,370 m).

360DVS2/ 360DVS3/ 360DVSL/ 360DVSR

CERTIFIED TO

ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

Gas Line Installation

When purging the gas lines, the window frame assembly must be removed.

The gas pipeline can be brought in through the vent end of the fireplace as well as the bottom. Knockouts (to allow gas pipe installation and testing any gas con- nection) are provided on the bottom behind the valve. It is most convenient to bring the gas line in from the vent end of the valve, as this allows fan installation or removal without disconnecting the gas line.

The gas line connection can be made with properly tinned 3/8” copper tubing, 3/8” rigid pipe, or an ap- proved flex connector. Since some municipalities have additional local codes, it is always best to consult your local authority and the CSA-B149.1 installation codes.

For USA installations, consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.

Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

1/2” Gas Supply

1/2” NPT X 1/2” Flare Shut-Off Valve

3/8” Flex Line

(From Valve)

FP297a

Fig. 5 Gas shutoff valve and flex connector.

10006326

9

Page 8
Image 8
Vermont Casting 360DVS2 Framing & Finishing, Final Finishing, Gas Specifications, Gas Inlet & Manifold Pressures, Natural