Vermont Casting LHERDV30 Troubleshooting the Gas Control System, LHEDV Series Direct Vent Insert

Models: LHECDV20 LHERDV30 LHECDV30 LHERDV20

1 32
Download 32 pages 7.47 Kb
Page 18
Image 18
START

LHEDV Series Direct Vent Insert

Troubleshooting the Gas Control System

START

Gas Supply On

YES

Honeywell Millivolt Valve

 

 

 

CHECK

NO

 

 

Supply Line Hooked Up

 

 

 

 

Shutoff Valve Open

Pilot Lights With Piezo Ignitor

Honeywell Millivolt Valve NO Manual background

Lockout Has Engaged. Wait

60 Seconds And Try Again.

For Spark At Electrode While

Depressing Piezo — 1/8" Gap To

Pilot Hood Needed.

All Wiring Connections

Replace Piezo Ignitor

YES

Pilot Stays Lit

YES

Pilot Lights Main Burner

YES

Manual backgroundManual background NO Manual background

Manual backgroundManual background NO Manual background

For Air In The Lines Thermopile Needs A Minimum 325mv. Adjust Pilot Flame Height. All Wiring Connections.

Replace Thermopile Thermocouple Needs A Minimum of 14mv.

Defective Valve. Turn To Pilot, Meter Should Read Greater Than 100 Mv. If Not, Replace.

Valve Is Turned On

On/off Switch Is Not Turned On. Watch For Grounded Wires! Thermopile Needs A Minimum 325mv.

Plugged Burner Orifice.

System OK.