Liner Installation

LHEDV Series Direct Vent Insert

Liner Installation

The collar extending down from the termination base is the air intake connector. Be sure the flex vent, which is connected to this collar, is also connected to the labelled air intake flue collar on the fireplace. Make sure the flex vent is attached on the correct collar and cap for exhaust as well.

Slide the insulation provided in the termination kit over the two (2) 3" flex liners, (to be attached to the 3" flue collar and cap of the termination). Feed one 3" flex vent from the bottom of the termination up through the 4" sleeve. Apply hi-temp sealant on the rain cap col- lar and slide the flex vent over the end of the rain cap collar fastening with the clamp provided. Slide the flex liner back down the 4" sleeve until 4" cap slides over

Flue gas exits through the vent termination rain cap

Outside combustion air enters through the lower level of the vent termination

Secure with clamp and three screws

1)Attach flexible pipe to rain cap

2)Secure with clamp

3)Attach raincap to vent termiantion us- ing three screws

Pull flexible pipe through vent termination

the sleeve. Attach cap to the sleeve with four (4) screws supplied. Apply hi-temp sealant over the air intake collar and attach intake flex vent in the same method. Feed the two flex liners down the chimney through the damper opening. Tighten termination to the chimney using the screws provided. (Fig. 10) NOTE: For Round Vent Terminations - tighten termination to the chimney by pushing the four (4) straps of the vent termination against the chimney and secure with four (4) screws provided. (Fig. 12)

In case the fireplace opening is only minimum height 21" (533 mm) and access from the front is not possible, follow the instructions below.

1.Remove flue collar plate assembly. Unbolt the top fastener plate and move it to the back first before sliding the flue collar plate out from the top of the unit. (Fig. 13)

2.Apply a bead of hi-temp sealant on the end of the collar before attaching the liner to the flue collar. Fasten it with two clamps then adjust fastener plate all the way to the back before sliding flue gas plate back onto the unit. (Figs. 14 and 15)

3.After the flue collar plate is set on the cabinet top, make sure the front edge of the flue collar plate is completely in contact with the back edge of the cabi- net top. (Fig. 16)

4.Put the machine screw back into the fastener plate. Bolt the plate until it is locked. (Fig. 17)

Under no circumstances should insulation be put between the damper and the top of the unit. This may cause condensation and overheating of the unit.

 

NOTE:

 

Minimum Vent Height

 

- 12 feet

 

Maximum Vent Height
Air Intake
- 35 feet

 

Air intake collar with

Exhaust

 

label secured with

Exhaust collar secured

clamp and three

screws

with clamp and three

 

screws

 

 

 

FP1280

Fig. 10

Liner installation.

 

 

 

Spring located in

 

 

 

between the liner

 

 

 

and chimney kit

 

HEDVCAK

 

 

 

Installation

 

 

 

Secure this

 

 

 

kit with three

 

Air Intake

 

(3) screws

 

6ft.

provided

 

 

 

 

(183cm)

 

 

 

Exhaust

 

HEZC Zero

 

 

Clearance Kit

 

 

FP1280a

Fig. 11 Liner installation with zero clearance kit.