Vermont Casting NVBR36 First Firing, Flame Adjustment, Flame Characteristics, Turn, to lower

Models: NVBC42 NVBR36

1 24
Download 24 pages 35.82 Kb
Page 13
Image 13
First Firing

NVB Series B-Vent Gas Fireplace

Middle Cross

Log

Left Cross

Log

Left Rear

Log

Ember

Left Log

Lava Rock

LG148

Fig. 16 NVB42 log placement.

Under no circumstances should lava rock be placed on any part of the burner assem- bly.

First Firing

Upon completing the gas line connection, a small amount of air will be trapped in the line. When first lighting the unit with pilot light, it will take a few minutes to purge the trapped air. Once purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lightings of the appli- ance will not require purging.

When lit for the first time, the appliance will emit a slight odor for an hour or two. This is due to paint and lubri- cants used in the manufacturing process. After each lighting, vapor may condense and fog the glass; this moisture disappears in a few minutes of burning.

Flame Adjustment

For units equipped with Hi/Lo valves, flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the center of the gas control.

 

Flame Characteristics

 

 

 

It is important to periodically perform a visual

Right Cross

check of the pilot and the burner flames.

Log

Compare them to the illustrations below

 

 

(Figs. 18, 19, 20). If any of the flames ap-

 

pear abnormal call a service person.

 

Inspecting the Venting System

 

 

 

The appliance venting system was designed

Right Rear

and constructed to develop a positive flow

Log

adequate to remove flue gases to the out-

 

 

side atmosphere.

Ember

Any foreign objects in the venting system,

except those designed specifically for the

Right

venting system, may cause spillage of flue

 

 

gases (i.e.: carbon monoxide) into the room.

 

To inspect the venting system, make sure

 

the main gas valve is off. Remove the glass

 

panel. Using a flashlight, check the combus-

 

tion dome and behind the top grille. Clean if

 

necessary.

Embers

 

Grate

 

Turn

 

Turn clockwise

counterclockwise

H

I

to lower

 

to increase

L

O

flame height

flame height

 

 

 

 

Fig. 17 Flame adjustment knob for SIT820 valve.

 

 

 

NOVA SIT PILOT

 

ELECTRONIC

 

IGNITION

Flame AdjustmentFlame Characteristics 3/8"-1/2"

FP581

Fig. 18 Proper pilot flame height.

7412950

13

Page 13
Image 13
Vermont Casting NVBR36 First Firing, Flame Adjustment, Flame Characteristics, Inspecting the Venting System, Turn, 7412950