NVB Series
Troubleshooting
Nova SIT 820 Standing Pilot
START
CHECK
Gas Supply On
YES
Pilot Lights with
Piezo Ignitor
YES
Pilot Stays Lit
YES
Pilot Lights Main
Burner
YES
NO |
|
|
| • Supply Line Hooked up | ||
|
| |||||
|
|
|
|
|
| • Shutoff Valve Open |
|
|
|
|
|
| • Lockout has engaged. Wait 60 |
|
|
|
|
|
| seconds and try again. |
|
|
|
|
|
| • Piezo not tight enough for good |
|
|
|
|
|
| ground. |
NO |
|
|
|
|
| • For spark at electrode while |
|
|
|
| |||
|
|
|
|
|
| depressing Piezo (Red Button) |
|
|
|
|
|
| 1/8" gap to pilot hood needed. |
|
|
|
|
|
| • All wiring connections |
|
|
|
|
|
| • Replace Piezo Ignitor |
|
|
|
|
|
| • Thermodisk |
|
|
|
|
|
| • For Air in the lines |
|
|
|
|
|
| • Thermopile needs a minimum |
|
|
|
|
|
| 325mV. Adjust pilot flame height. |
|
|
|
|
|
| • All wiring connections |
NO |
|
|
|
| • Replace Thermopile | |
|
|
| ||||
|
|
|
|
|
| • Thermocouple needs a minimum |
|
|
|
|
|
| of 14mV. |
|
|
|
|
|
| • Defective valve. Turn to pilot, |
|
|
|
|
|
| meter should read greater than |
|
|
|
|
|
| 100mV. |
|
|
|
|
|
| • Thermodisk |
|
|
|
|
|
| • Wall switch is not turned on. |
|
|
|
|
|
| Watch for grounded wires! |
NO |
|
|
| • Thermopile needs a minimum | ||
|
|
| ||||
|
|
|
|
|
| 325mV |
|
|
|
|
|
| • Plugged burner orifice |
System OK