NOVA SIT 822 with Honeywell S8600 B Electronic Ignition

START

Turn gas supply off

Turn ON/OFF Switch to call for heat.

Power to module

(24V nominal)

YES

Spark across

Ignitor Sensor gap

YES

Turn gas on Pilot burner lights?

YES

Spark stops when pilot is lit?

YES

Remove glass panel before servicing.

NO

CHECK : • Line Voltage (120VAC)

 

• Low Voltage Transformer

 

 

(19.5 minimum VAC)

 

 

• ON/OFF Switch

 

 

 

 

• Wiring connections

 

 

• Thermodisk

 

 

 

 

Unplug Ignition Lead

NO

 

 

and check spark

• Replace Module

NO

 

 

at module

 

 

 

(24VAC nominal)

Spark OK?

YES Remove glass panel before servicing.

Check ignition cable, ground wiring, Ceramic Insulator and gap. Correct as necessary

Check boot of ignition cable for signs of melting or buckling. Take protective actions to shield cable and boot from excessive temperatures.

Check that all manual gas valves are open, supply tubing and pressures are good,

NO and pilot burner orifice is not blocked.

Check electrical connections between module and pilot operator on gas control.

Check for 24VAC across PV-MV/PV terminals on module. If voltage is okay, replace gas control. If not, replace module.

NO

NOTE: If S8600B goes into lockout, reset system.

 

Check continuity of ignition cable and ground wire.

 

Clean flame rod.

 

Check electrical connections beween flame rod and module.

 

Check for cracked ceramic flame rod insulator.

 

Check that pilot flame covers flame rod and is steady blue.

 

Adjust pilot flame.

 

If problem persists, replace module.

Main Burner lights?

NO

 

 

 

 

 

YES

 

 

 

 

 

 

 

System runs until

NO

ON/OFF switch is in

"OFF" position

 

 

YES Manual background

Check for 24VAC across MV-MV/PV terminals. If no voltage, replace module.

Check electrical connections between module and gas control. If okay, replace gas control or gas control operator.

NOTE: If S8600B goes into lockout, reset system.

Check for continuity of igniton cable and ground wire. NOTE: If ground is poor or erratic, shutdowns may occur occasionally even though operation is normal

at time of checkout.

Check that the pilot flame covers flame rod and is steady and blue.

If checks are okay, replace module.

Troubleshooting

Ends