NVB Series
Optional Accessories
Fan Kit
The FK12 fan kit is available for use on the NVBC36 and NBVC42 model appliances only.
Auxiliary fan systems increase the efficiency of the cir- culation of the heating air. The FK12 fan assembly is a fixed speed fan system and does not allow for variable speed control.
Installation
Remove the 2 ceramic fiber refractory panels by care- fully lifting them out of the fireplace. Next, remove the access panel by pulling it up and out from the side edge of the panel. Use caution — the panel edges may be sharp.
Center the fan assembly over the mounting location and secure it with the Velcro® strips at the back of the fireplace.
Insert the plug into the receptacle (EB1) located against the lower right side wall of the fireplace.
Caution: Be sure that no wires are pinched.
Prior to reinstalling the access panel and the hearth brick, it is advisable to operate the wall switch on and off to assure fan operation. If the fan does not operate and you are assured that 115 VAC power is present at the receptacle, contact your Dealer.
Reinstall the access panel and hearth brick by reversing Step 1.
WARNING: Never contact blower wheels during operation.
Speed Control
The SCVS variable speed control is available to allow speed adjustment of the fan.
Electrical Connection
The
Glass Doors
Appliance Models | Glass Doors |
NVBR36/NVBC36 | 36GSKBB |
| 36GDKBB |
| 36GDKBK |
| 36GDKDP |
| 36GDKS |
Appliance Models | Glass Doors |
NVBR42/NVBC42 | 42GSKBB |
| 42GDKBB |
| 42GDKBK |
| 42GDKDP |
| 42GDKS |
Outside Air Kit
The Model
Thermal Vent Damper
Installing the TVD6/7 Thermal Vent Damper reduces cold air infiltration when fireplace is not in use by open- ing and closing automatically.
Attach the thermal vent damper to the combustion dome with 2 screws. Be sure the tab points down. (Fig. 21)
Start the appliance and operate it for approximately 5 minutes. Turn the unit off and check if the vent damper is in the open position (blades down from the horizontal position). If the damper has not opened, check installa- tion.
Tab
Thermal Vent Damper
Screws
FP577
Fig. 21 Attach the thermal vent damper.
Remote Controls
Optional remote control units are available to control different functions of the appliance.
Model | Function/s Controlled |
RC1 | “ON/OFF” |
RC2 | “ON/OFF” and Temperature |
MRC3 | “ON/OFF” and Temperature control |
| with a digital and a programmable 24 |
| hour clock |
|
|
| Shrouds |
|
|
Decorative shrouds are available to enhance the ap- pearance of the termination cap.
Square Shroud | SLSBL |
22 | 7412950 |