Vermont Casting RDVOD 3350 Local Path, On Path, Radiance Direct Vent/Natural Vent Gas Heater

Models: RDVOD 3360 RDVOD 3369 RDVOD 3354 RDVOD 3350 RDVOD 3399 RDVOD 3390

1 40
Download 40 pages 19.6 Kb
Page 28
Image 28
Local Path

Radiance Direct Vent/Natural Vent Gas Heater

Comfort Valve System Control Sequence Of Operation With Transmitter

Set manual switch

 

 

Five minute wait

to local or remote

 

 

period

 

 

 

 

 

 

 

 

 

 

Light pilot burner

Did the LED stop

blinking?

Release pilotstat

knob.

Yes

Turn pilotstat knob from PILOT to ON.

 

No

Review LED fail-

 

 

 

ure analysis.

 

 

 

 

 

 

 

Cycle switch

once and leave in remote. Press any On Path key on transmit- ter for recognition

operation.

Choose Manual or Remote path. Set switch to manual or remote.

Local Path

On Path

If manual switch is Manual background set to LOCAL, did Manual background main burner light and fan turn on?

Yes

Turn pilotstat knob

Move switch from

local to remote.

Press any key on transmitter. Move switch back to local.

If the manual switch is set to REMOTE, press the mode but-

ton to display “ON”. Manual background does transmitter con-

trol the main burner

and fan?

Move switch from manual to remote. Press any key on transmitter.

to PILOT to turn off main burner.

Turn pilotstat knob

to OFF to turn

valve completely

off.

Yes

 

Does transmitter

No

 

change levels of

 

 

 

 

 

 

 

 

 

 

flame height, fan

 

 

 

speed?

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

Set levels of flame

 

 

height and fan to

 

 

“0” to shut off main

 

 

burner

 

and fan.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn pilotstat knob

to OFF to turn

valve completely

off.

2828

20004188

Page 28
Image 28
Vermont Casting RDVOD 3350, RDVOD 3399 manual Local Path, On Path, Radiance Direct Vent/Natural Vent Gas Heater, 20004188