Vermont Castings Radiance

Clearance Requirements

Minimum Clearances to Combustible Materials

Maintain clearance, (empty space), between combus- tible materials and the heater as specified below.

Freestanding Stove

 

 

A

B

D

C

 

 

ST101

A:Maximum Mantel Depth .............. 7Z\x" (190.5mm)

B:To Side Wall / Trim* ........................ 4" (101.6mm)

C:To Rear Wall ................................... 4" (101.6mm)

D:To Mantel / Trim* ... 16" (406.4mm) / 2" (50.8mm)

* Trim is 1" thick max.

Fig. 5 Freestanding Clearances.

A

B

C

ST185

A = Depth, Mantel and/or Top Trim

B = Height from top of heater

C= Min. 10"

When:

 

A = 7Z\x" (190mm) max.

A = 3” (75mm) max.

B = 16" (406mm) min.

B = 11Z\x" (292mm) min.

A = 6" (152mm) max.

A = 1Z\x" (38mm) max.

B = 14Z\x" (368mm) min.

B = 10" (254mm) min.

A = 4Z\x" (114mm) max.

 

B = 13" (330mm) min.

 

 

 

Fig. 6 Mantel Clearances.

 

Alcove Clearances

The Radiance Unvented heater may be installed in an alcove constructed to maintain the clearances speci- fied below.

B

 

 

 

B

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

D

ST103a

A: Maximum Alcove Depth

24" (609mm)

B: To Side Wall

4" (101mm)

C: To Rear Wall

4" (101mm)

D: To Ceiling

60" (1524mm)

Fig. 7 Alcove Clearances.

Hearth Requirements

The Radiance Unvented heater must be installed on rigid flooring. If the appliance is installed on any combustible surface other than wood flooring, such as carpet or tile, a metal or wood panel must be installed to extend the full length and width of the unit. There are no other hearth or floor protection requirements.

WARNING

Do not install this heater in a bathroom or bedroom.

Installation of this heater must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.

This heater creates warm air currents. These currents move heat to wall surfaces next to the heater. Installing the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air such as tobacco smoke exist, may discolor walls.

Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.