Radiance
| Rheostat |
Retaining Nut |
|
Control Knob | ST347a |
Fig. 14 Attach rheostat to control panel. Valve may look dif- ferent.
| MOTOR | Disconnect power |
|
| before servicing. |
BLK | BLK | BLK SNAPSTAT |
|
| |
| BLK | WHT |
WHT | GRN | ON/OFF |
RHEOSTAT | ||
| POWER |
|
ST196
Fig. 15 #2767 / FK26 Fan Wiring Diagram
WARNING
The optional fan kit is equipped with a
NOTE: If you are installing the fan kit after the stove is in its final location, follow same steps mentioned previ- ously with the exception of disengaging only the right side of the outer shroud.
Install ON/OFF Switch
The switch assembly parts are found in the parts bag.
1.Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud. (Fig. 16)
2.Run wires down back of stove, under bottom of rear shroud to valve.
3.Attach wires to valve terminals. (Fig. 17)
Switch As- | Existing | |
sembly | ||
Holes | ||
|
Screws | ST315 |
|
Fig. 16 Attach switch assembly to rear shroud.
TH |
TP |
TPTH |
ST228
Fig. 17 Attach switch wires to valve.
Thermostat Connection (Optional)
Use only a thermostat rated for 500 - 750 millivolts. Do not use low voltage (24V) thermostats.
Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your
installation. |
|
Thermostat Wire / Gauge | Maximum Run |
18 | 40 feet |
20 | 25 feet |
22 | 16 feet |
1.Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.
2.Connect the thermostat wires to the valve. (Fig. 17)
12 | 20004555 |