Vermont Casting SDDVT manual Operation, Thermostat Connection optional, Install the Front Plate

Models: SDDVT

1 52
Download 52 pages 24.24 Kb
Page 29
Image 29
Thermostat Connection (optional)
Maximum Run
20 feet
20 - 40 feet up to 60 feet

Stardance Direct Vent/Natural Vent Gas Heater

Thermostat Connection (optional)

Use only a thermostat rated for 500 millivolts.

Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation.

Thermostat

Wire / Gauge

18

16

14

1.Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.

2.Connect the thermostat wires to the valve. (Fig. 51)

Install the Front Plate

Hold the front plate by the window bars and lift it into position, engaging the two steel tabs on the top corners behind the adjacent bosses in the side plates. (Fig. 52) Then seat the Front against the sides so the tabs at the bottom lip engage with the notches in the stove legs.

When properly installed, the bottom of the Front Plate cannot be pulled away from the sides without also lifting it.

Engage steel tabs gehind the cast iron bosses

Control Door

Bottom tabs engage

 

notch in the leg.

ST474

Fig. 52 Install the front plate.

This completes assembly of the Stardance stove.

Operation

�������

��������������

������������

������������������

�������������

��������������������

���������������

The Stardance is operated with the front plate in place with the doors open or closed. To open the front doors, pull forward to separate the magnetic catch.

CAUTION: DO NOT TOUCH DOORS WHEN HOT!

Your First Fire

Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly, Figure 53. Follow the lighting instructions on Page 31 exactly.

During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within an hour or so, however, you can open a window to provide fresh air to alleviate the condition.

ST935

Fig. 53 Pilot assembly location.

Pilot and Burner Inspection

Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figure

55.If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for as- sistance. Do not operate the heater until the pilot flame is correct.

Follow regular maintenance procedures as described on Page 41.