Stardance Direct Vent/Natural Vent Gas Heater
Fuel Conversion Instructions
WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- tions is not followed exactly, a fire, explosion
or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is respon- sible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before pro- ceeding with the conversion.
|
| Main Gas |
| Gas Supply Inlet | Line |
ST226a |
| |
|
|
Fig. 59 Attach the gas line to the left side of the valve.
Conversion Precautions
Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.
Conversion Procedure
1.Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 41, Fig. 75)
2.Swing open the swiveling latches at the top left and right corners of the glass frame. (Page 42, Fig. 76)
3.Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a coun- ter protected by a towel.
4.Remove the logset from the firebox.
Valve Conversion
SDDVT Series Models
1.Turn control knob to the OFF position, and shut off the gas supply to the valve.
2.Allow the valve to cool to room temperature.
3.Remove the black protection cap by hand. (Fig. 60)
4.Insert a 5/32” or 4 mm Allen wrench into the hexago-
nal |
| |
the screw (Fig. |
| |
61), rotate it | Figure 60 | |
counterclock- | ||
Figure | ||
wise until it | 61 | |
is free and |
| |
extract it. | � | |
5. Check that the | � | |
� | ||
| ||
screw is clean | � | |
| ||
and if neces- | � | |
sary remove | ||
� | ||
| ||
dirt. | � | |
� | ||
| ||
6. Flip the screw. |
| |
(Fig. 62) | Figure 62 | |
7. Using the Al- |
| |
len wrench as | Figure 63 | |
shown in Figure | ||
| ||
63, rotate the |
| |
screw clockwise | � | |
| ||
and tighten until | � | |
� | ||
snug. | � | |
| ||
WARNING: Do |
| |
not overtighten |
| |
the screw. Rec- |
| |
ommended to |
| |
grip the wrench | � | |
| � | |
by the short | � | |
� | ||
| ||
side. |
| |
8. Verify that if the |
| |
conversion is from NG to LP, the | ||
screw must be reassembled with the red | ||
ible. (Fig. 64) |
|
9. Replace the black protection cap.
WARNING: Check that also the pilot and main burner injectors are appropriate for the gas type.
Figure 64 |
| Natural Gas | ||
LP Configuration | ||||
Configuration | ||||
|
| |||
| � |
| � | |
| � |
| � | |
| � |
| � | |
| � |
| � | |
| Red |
|
| |
| Red | CO141 |
SDDVTC Series Models
1.Follow procedure for pilot type 2 to replace pilot orifice.
2.Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 32, Fig. 56)
20012734 | 37 |