Stardance Direct Vent/Natural Vent Gas Heater

Maintenance

Your Stardance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly.

Annual System Inspection

Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts.

Logset and Burner /

Cleaning and Inspection

Cleanliness is critical to the proper function of the heater. The logset and burner must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean as necessary.

1.Turn the burner OFF and let the heater cool com- pletely before cleaning.

2.Lift the Stove Front up and then swing the bottom out to disengage it from the heater shell. (Fig. 75)

3.Carefully remove the glass and frame assembly and place it out of the way on a flat, padded surface such as a counter protected by a towel.

4.Carefully inspect the Logs for damage. Contact your local dealer if any damage is evident. DO NOT OP-

ERATE THE HEATER WITH DAMAGED LOGS.

5.Use a soft bristled brush to sweep dust or debris from the Logs, Pilot and Burner. Use care as the logs are fragile and susceptible to damage. DO NOT USE

A VACUUM TO CLEAN THE LOGS OR BURNER.

6.Replace the glass panel and frame assembly.

7.Replace the Stove Front.

Care of Cast Iron

An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the logs, burner and valve assembly, glass and frame assembly. Apply the paint sparingly; two light coats of paint will give bet- ter results than a single heavy coat.

Clean porcelain enamel surfaces with a soft, damp cloth. Do not use abrasive cleaning agents. If neces- sary, use only a cleaning agent formulated especially for use on porcelain enamel surfaces.

CAUTION

TURN THE PILOT OFF BEFORE PAINTING. AL- LOW THE HEATER TO COOL COMPLETELY BE- FORE PAINTING.

Cleaning the Glass

WARNING: Allow the glass to cool com- pletely before attempting to clean.

�������

��������������

������������

������������������

�������������

��������������������

���������������

It will be necessary to clean the glass periodically. Dur- ing start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-ammonia household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depend- ing on the circumstances present.

Clean glass after first two weeks of opera- tion.

Glass Replacement

Replace glass only with CFM Corporation approved parts. Refer to Page 44 for Replacement Parts. Refer to Figures 75 & 76 for removal of the damaged glass frame.

ST474a

Fig. 75 Remove the stove front.

20012734

41

Page 41
Image 41
Vermont Casting SDDVT Maintenance, Annual System Inspection, Logset and Burner Cleaning and Inspection, Cleaning the Glass

SDDVT specifications

Vermont Casting's SDDVT, or the Signature Series Direct Vent Technology, represents a remarkable blend of design, efficiency, and functionality in the world of high-performance heating appliances. Known for its commitment to craftsmanship, Vermont Casting has long been synonymous with quality, and the SDDVT is no exception.

One of the standout features of the SDDVT is its advanced direct venting capability. This system allows for efficient venting of combustion gases directly outside, minimizing the risk of backdrafting and ensuring optimal indoor air quality. It draws air from the outside for combustion, creating a more controlled environment that enhances both efficiency and safety. Homeowners can rest easy knowing that the SDDVT provides a reliable heating solution while protecting indoor air quality.

Another significant aspect of the SDDVT is its high-efficiency performance. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, the SDDVT maximizes heat output while minimizing fuel consumption. This efficiency translates to lower energy bills and a reduced carbon footprint, making it an environmentally friendly choice for heating. The unit is designed to operate effectively even in extremely cold temperatures, ensuring comfort throughout the winter months.

The SDDVT also boasts an array of customizable options that appeal to a wide range of aesthetic preferences. Available in various finishes and styles, including traditional cast iron and sleek modern designs, homeowners can select a model that complements their decor. The unit features a large viewing glass that provides an unobstructed view of the flames, creating a cozy ambiance that enhances the living space.

Incorporating cutting-edge technology, the SDDVT includes electronic ignition and advanced control systems, allowing users to easily manage their heating preferences. The integration of smart technology enables compatibility with home automation systems, giving users added convenience and control.

Overall, Vermont Casting's SDDVT is an exemplary heating solution characterized by its innovative direct venting technology, high efficiency, and customizable design options. With a focus on quality and performance, this unit exemplifies the brand's dedication to providing sustainable and effective heating solutions tailored to modern living. Whether for new construction or retrofitting existing spaces, the SDDVT stands as a premier choice for comfort and style.