FT-60R OPERATING MANUAL10

LOW BATTERY INDICATION
As your battery discharges during use, the voltage will gradually become lower. When
the battery voltage is becoming too low for reliable operation,
the “ ” icon will blink on the LCD display, indicating that the
battery pack must be recharged before further use.
Avoid recharging Ni-MH batteries before the “ ” indicator is observed, as this can
degrade the charge capacity of your Ni-MH battery pack.
INSTALLATION OF FBA-25A ALKALINE BATTERY CASE (OPTION)
The optional FBA-25A Battery Case allows operation of the FT-60R using six “AA” size
Alkaline batteries.
When installing batteries, insert the (–) end first, then press in the (+) end so the battery
snaps into place. Always replace all six batteries at the same time, paying attention to the
polarity indicated inside the case.
The FBA-25A must not be used with rechargeable cells. The FBA-25A does not contain
the thermal and over-current protection circuits (provided in the “FNB” series of Ni-MH
Battery Packs) required when utilizing Ni-Cd and Ni-MH cells.
Note that the power output and battery life will be much shorter when using Alkaline AA
cells. They should be considered an emergency backup power source only, for this rea-
son.
INSTALLATION OF ACCESSORIES