Operation

Save Settings: For each input and supported resolution, the DView lets you save image quality settings as presets that you can recall at a later time. You can create up to three presets – designated “Custom,” “ISF Day” and “ISF Night” – per input and resolution.

You should save changes to any of the following settings to a preset; otherwise they will be lost when a new input source or resolution is selected:

Brightness

Contrast

Color saturation

Tint

Sharpness

Gamma

Color temperature and white balance

To save image settings to a preset, select Save Settings from the ISF Calibration menu and select “Custom,“ “ISF Day” or “ISF Night.”

White Balance: To remove any trace of color from the white areas of the projected image, choose White Balance from the Picture Adjust menu and press ENTER.

Gain: Use the Gain controls to correct color imbalances in the bright areas of the image. A good way to do this is to use a test pattern consisting mostly of solid white areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red, green or blue, decrease the Gain for that color.

Offset: Use the Offset controls in the White Balance sub-menu to correct color imbalances in the dark areas of the image. A good way to do this is to use a test pattern consisting mostly of dark gray areas, such as a 30 IRE “window” pattern. If the gray areas contain traces of red, green or blue, decrease the Offset for that color.

Any white balance adjustments you make here are automatically stored

Note

as a “Custom” color temperature.

 

White Balance

R Gain

100

G Gain

100

B Gain

100

R Offset

50

G Offset

50

B Offset

50

 

 

Blue Enable: Blue Enable removes all red and green color information from the image, simulating a blue filter. You can use it instead of a blue filter when performing color and tint adjustments.

Baud Rate: Select Baud Rate from the ISF Calibration menu to set the data transfer rate of the DView’s RS-232 SERVICE port. (This setting must match the data rate of the device connected to the RS-232 input.)

Serial Link: Select Serial Link from the ISF Calibration menu to configure the RS-232 Service port (see Figure 3-11)for normal operation (On) or for software upgrades (Off).

Factory Reset: To reset all DView settings to their factory defaults, select Factory Reset from the ISF Calibration menu and press ENTER. This command is not undoable. Use it with caution!

Vidikron VL-40 and VL-46 Owner’s Operating Manual

43

Page 53
Image 53
Vidikron VL-40 manual 100