ENGLISH

Other Information

If the Command is Not valid, Command Type= “-”, Only for HDTV power status on standby.

Name

Length

Command

CR

 

 

Type

 

 

 

 

 

Byte Count

1 Byte

1 Byte

1 Byte

Bytes order

1

2

3

 

 

 

 

Example1: Get power status on standby and this command is valid.

Send (Hex Format)

Name

Length

Command

Command

Value1

Value2

Value3

CR

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

Hex

0x36

0x67

0x6C

0x30

0x30

0x30

0x0D

 

 

 

 

 

 

 

 

Reply (Hex Format)

Name

Length

Command

Command

Value1

Value2

Value3

CR

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

Hex

0x36

0x72

0x6C

0x30

0x30

0x30

0x0D

 

 

 

 

 

 

 

 

Example2: Get Brightness from TV-05 and this command is valid.

The Brightness value is 67.

Send (Hex Format)

Name

Length

ID

Command

Command

Value1

Value2

Value3

CR

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hex

0x38

0x30

0x67

0x62

0x30

0x30

0x30

0x0D

 

 

0x35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reply (Hex Format)

Name

Length

ID

Command

Command

Value1

Value2

Value3

CR

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hex

0x38

0x30

0x72

0x62

0x30

0x36

0x37

0x0D

 

 

0x35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example3: Get Brightness from TV-05 , but the Brightness command ID is error and it is NOT in the command table.

Send (Hex Format)

Name

Length

ID

Command

Command

Value1

Value2

Value3

CR

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hex

0x38

0x30

0x67

0xD3

0x30

0x30

0x30

0x0D

 

 

0x35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reply (Hex Format)

Name

Length

ID

Command

CR

 

 

 

Type

 

 

 

 

 

 

Hex

0x34

0x30

0x2D

0x0D

 

 

0x35

 

 

 

 

 

 

 

ViewSonic

43

VT3205LED

Page 54
Image 54
ViewSonic VS13915-1M warranty 0x36 0x67 0x6C 0x30 0x0D