ViewSonic VS13915-1M Remote Control Pass-through mode, RCU Pass-through Command description

Models: VS13915-1M

1 63
Download 63 pages 47.82 Kb
Page 57
Image 57

Other Information

6. Remote Control Pass-through mode

When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU shall have no effect on the monitor function. For example: “+Volume” will not change the volume in the LCD but only sends “+Volume” code to PC over the RS232 port.

RCU Pass-through Command description:

Length

Total Byte of Message excluding “CR”

 

 

TV ID

Identification for each of TV

 

 

Command Type

Identify command type,

 

“p” (0x70h) : RCU Pass-through

 

 

Value[1~2]

Two bytes ASCII that defines the value

 

 

CR

0x0D

 

 

RCU Pass-through Command Format:

Reply: (Command Type= “p”)

Name

Length

ID

Command

Value1

Value2

CR

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

Byte Count

1 Byte

2 Byte

1 Byte

1 Byte

1 Byte

1 Byte

 

 

 

 

 

 

 

Bytes order

1

2~3

4

5

6

7

 

 

 

 

 

 

 

Example1: User press “Menu” Key form RCU to TV-03 and RCU data pass-through to Server, then server will receive “1A”.

Reply (Hex Format)

Name

Length

ID

Command

Value1

Value2

CR

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

Hex

0x36

0x30

0x70

0x31

0x41

0x0D

 

 

0x33

 

 

 

 

 

 

 

 

 

 

 

Example2: User press “5” Key form RCU to TV-07 and RCU data pass-through to Server, then server will receive “05”.

Reply (Hex Format)

Name

Length

ID

Command

Value1

Value2

CR

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

Hex

0x36

0x30

0x70

0x30

0x35

0x0D

 

 

0x36

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

ViewSonic

46

VT3205LED

Page 57
Image 57
ViewSonic VS13915-1M warranty Remote Control Pass-through mode, RCU Pass-through Command description