Other Information

6. Remote Control Pass-through mode

When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU shall have no effect on the monitor function. For example: “+Volume” will not change the volume in the LCD but only sends “+Volume” code to PC over the RS232 port.

RCU Pass-through Command description:

Length

Total Byte of Message excluding “CR”

 

 

TV ID

Identification for each of TV

 

 

Command Type

Identify command type,

 

“p” (0x70h) : RCU Pass-through

 

 

Value[1~2]

Two bytes ASCII that defines the value

 

 

CR

0x0D

 

 

RCU Pass-through Command Format:

Reply: (Command Type= “p”)

Name

Length

ID

Command

Value1

Value2

CR

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

Byte Count

1 Byte

2 Byte

1 Byte

1 Byte

1 Byte

1 Byte

 

 

 

 

 

 

 

Bytes order

1

2~3

4

5

6

7

 

 

 

 

 

 

 

Example1: User press “Menu” Key form RCU to TV-03 and RCU data pass-through to Server, then server will receive “1A”.

Reply (Hex Format)

Name

Length

ID

Command

Value1

Value2

CR

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

Hex

0x36

0x30

0x70

0x31

0x41

0x0D

 

 

0x33

 

 

 

 

 

 

 

 

 

 

 

Example2: User press “5” Key form RCU to TV-07 and RCU data pass-through to Server, then server will receive “05”.

Reply (Hex Format)

Name

Length

ID

Command

Value1

Value2

CR

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

Hex

0x36

0x30

0x70

0x30

0x35

0x0D

 

 

0x36

 

 

 

 

 

 

 

 

 

 

 