TROUBLESHOOTING GUIDE

 

PROBLEM

POSSIBLE CAUSE

CORRECTION

 

 

Low ice production. Unit

Low water level in reservoir.

Make sure that the reservoir drain plug is

 

 

is running, has run over a 48

 

installed properly. Check the water line to

 

 

hour period, and there is

 

the unit to make sure there are no restrictions

 

 

little ice in bin.

 

or kinks in the line. Check all filters to make sure

 

 

 

 

they are not restricted or plugged.

 

 

 

Distributor tube is restricted.

See “Cleaning the Ice Machine System” section for

 

 

 

 

cleaning the unit for proper operation.

 

 

 

Build-up of deposits on evaporator

See “Cleaning the Ice Machine System”

 

 

 

plate.

section for cleaning the unit for proper operation.

 

 

 

Inadequate drain system.

Restriction in drain lines will cause ice in the bin to

 

 

 

 

melt to a thinner cube. If using a gravity drain,

 

 

 

 

make certain there are no kinks or restrictions in the

 

 

 

 

drain lines. If using a drain pump, check the inlet

 

 

 

 

screen, discharge line, and vent line for any build-up

 

 

 

 

or restrictions.

 

 

 

Condenser fan air flow is restricted

Make certain the grill in the front of the unit is free

 

 

 

 

and open for proper air circulation. Check and

 

 

 

 

clean the condenser coil by removing the grill in the

 

 

 

 

front of the unit. Clean the condenser with a

 

 

 

 

vacuum and brush attachment.

 

 

Grid cutter is not cutting

The selector switch is not in the

Set the rocker switch on the grill of the ice

 

 

ice slab.

“ON” position.

machine to the “ON” position.

 

 

 

The grid cutter is not plugged into

Remove the escutcheon panel and plug the

 

 

 

receptacle.

grid cutter into the receptacle on the side of the

 

 

 

 

liner.

 

 

 

It has not had time to cut

It can take up to 35 minutes to cut through a

 

 

 

through the slab.

harvested ice slab. This is normal operation.

 

 

Ice level is too low.

The ice machine is not level

Use a level to check the unit from side to side and

 

 

 

 

front to rear.

 

 

 

Room temperature is too cold.

Move the unit to an area where temperature is

 

 

 

 

above 55oF.

 

 

 

The selector switch is not in the

Set the rocker switch on the grill of the ice

 

 

 

“ON” position.

machine to the “ON” position.

 

 

Ice level is too high.

The ice machine is not level

Use a level to check the unit from side to side and

 

 

 

 

front to rear.

 

 

 

Room temperature is too warm.

Move the unit to an area where temperature is

 

 

 

 

below 90oF.

 

 

 

Ice deflector is not in place or

Check to see that the ice deflector is in place

 

 

 

secured properly.

and secured below the grid cutter.

 

 

 

Bin level sensing tube needs

Adjust the bin level sensing tube by simply

 

 

 

adjusting.

pressing directly down on the tube 5 inches from

 

 

 

 

the front of the tube to get a desired bin level.

 

 

Water keeps backing up

Inadequate drain system.

Restriction or improperly installed drain lines

 

 

into ice bin (gravity drain).

 

will cause water to back up into the ice bin. Make

 

 

 

 

certain there are no kinks or restrictions in the drain

 

 

 

 

lines. If necessary, consult a qualified plumber.

 

 

 

Foreign material in ice bin drain

Foreign material is restricting or blocking the ice bin

 

 

 

 

drain located at the right rear corner of the ice bin.

 

 

 

 

The drain will need to be cleared.

 

 

 

 

 

 

18

Page 18
Image 18
Viking 15 W Low ice production. Unit Low water level in reservoir, Is running, has run over a, Hour period, and there is