Viking F20518A manual Connecting Gas & Electrical 30W Final Installation 30W

Models: F20518A

1 14
Download 14 pages 61.67 Kb
Page 9
Image 9

Connecting Gas & Electrical (30”W.)

Final Installation (30”W.)

1

2

DANGER

Gas leak hazard.

To avoid risk of personal injury or death; leak testing of the appliance must be conducted

according to the manufacturer’s instructions. Before placing appliance in operation, always check for gas leaks with soapy water solution.

• DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

WARNING

Electrical shock hazard.

To avoid the risk of electrical

shock, personal injury or death; verify your appliance has been

properly grounded in accordance with local codes or in absence of codes, with the National Electrical Code (NEC). ANSI/NFPA 70-latest edition.

Remove racks.

Unscrew pallet screws from side of oven.

1

Note: Refer to “Electrical & Gas Requirements” section for proper installation information.

Connect gas and electrical. Before placing appliance in operation, always check for gas leaks. This must be performed by your dealer, a qualified licensed plumber, or gas service company.

3

4

Lift oven into position.

Push oven straight into cabinet.

5

6

Attach screws to the side of the framing.

Replace racks.

Note: Four screws (two on each side).

 

(Screws not included.)

 

16

17