4 TO OVERWRITE
CURRENT PROGRAM

DISPLAY WINDOW - This area, depending on what button is pressed, displays a variety of operation messages. A “READY” message appears when there is power to the machine.

OWNER CONTROLS - A control panel accessible by pressing the Vita-Mix logo.

Press once to reveal the mode message. Press button

 

READY

 

1 then 6 within five seconds to continue. Once the correct code

 

 

 

 

 

 

is entered the display will indicate the motor temperature

 

 

 

(NORM, WARM, HOT), a usage count and a total. The

MODE

 

 

“COUNT” is a machine usage total and can be reset. This

 

 

can be used to keep a count of the number of drinks sold in

 

 

 

 

 

 

a week, day or even an hour. To clear, press and hold the

TEMP

COUNT

TOTAL

START/STOP button for 5 seconds. The “TOTAL” keeps track

 

NORM

25

100

of the machine usage, including production and testing, and

 

 

 

 

 

 

cannot be cleared.

VITA-MIX SMOOTHIE

Press twice to reveal the name of the program controlling

the PRE-SET buttons. If you are using the MP settings,

 

PROGRAM

 

this will read VITA-MIX SMOOTHIE PROGRAM.

Press a third time to reveal an option to reset the

PRE-SET buttons to the original factory settings.

Press a fourth time to exit and continue blending.

HIGH/LOW PULSE button - The pulse provides a quick increase or decrease in speed of the blades when blending. Press H to increase the motor to speeds that range from 51%-100%. Press L to decrease the motor speed down to a range of 50% -7%. The PULSE button will override the running program (as long as it is depressed). Once released the original program continues its cycle.

The PULSE high (H) and low (L) speed is set by using the SPEED CONTROL buttons. To set, while pressing and holding a PULSE button, press the SPEED CONTROL or button until the desired motor speed is reached. The PULSE speed will remain at this setting until changed again with the SPEED CONTROL buttons.

5

Page 5
Image 5
Vita-Mix XTG012 owner manual NORM, WARM, HOT, a usage count and a total, Cannot be cleared