Vita-Mix XTG012 owner manual In-CounterGasket, Gasket Installation Instructions

Models: XTG012

1 28
Download 28 pages 17.8 Kb
Page 12
Image 12
In-Counter Gasket

In-Counter Gasket

Gasket Installation Instructions:

1.Follow the instructions on page 10 on preparing the counter area for the installation of your In-Counter Blending Station® MP. Also, use the Template Sheet (provided in your machine’s original package) to assist you in the placement and ventilation of your machine.

2.Lay the blender on its back with the motor pointing toward you. Allow 1-2 in.

(3 -5 cm) of the motor base to hang over the edge of the counter top to facilitate easy fitting of the gasket.

3.Slide the power cord through the gasket, with the groove of the gasket pointing toward the machine base.

4.Starting at one corner of the motor base, press the gasket onto the motor base, so that the groove in the gasket seats itself onto the stepped bottom edge of the motor base.

5.Working around the bottom edge of the motor base, press the gasket onto the motor base until the entire perimeter of the gasket is firmly attached to the motor base.

6.Carefully place the blender into the hole in the counter.

7.Be sure that the gasket is properly seated on the motor base and against the counter top.

8.Do not secure the machine to the counter with bonding materials.

This gasket was designed to protect your machine from water damage and to reduce noise. Failure to properly install this gasket could result in moisture damage.