DLP Projjecttor—User’s Manuall
Option
The Option tab contains miscellaneous setup menu settings such as Power management and De- fault input select and can be accessed by using the Setting menu.
The following table lists all functions with a description and the default setting.
| LABEL |
|
| DESCRIPTION |
|
|
|
|
|
|
|
| Power management |
|
| Select the amount of time the projector remains idle before powering down. |
|
|
|
| Range: Off, 0:05, 0:10, 0:20, 0:30 |
| |
|
|
|
|
| |
|
|
|
| Set this item to On to enable the projector to automatically lower the projection |
|
| Screen trigger |
|
| screen when powering on. |
|
|
|
|
| Range: On or Off |
|
| Fan control |
|
| Select Fan control. |
|
|
|
| Range: Normal or Max (see Fan control page 73) |
| |
|
|
|
|
| |
|
|
|
| Select the default input for projection. |
|
| Default input select |
|
| Range: Last, Auto, Computer1, Computer2, Computer3, Component, Video, S- |
|
|
|
|
| Video |
|
| Color System |
|
|
| |
|
|
|
| ||
|
|
|
|
| |
| Message |
|
| This option turns on or off messages. |
|
|
|
| Range: Off or On |
| |
|
|
|
|
| |
|
|
|
| Set this item to on to have the projector display a message when the air filter |
|
| Filter warning |
|
| needs servicing. |
|
|
|
|
| Range: Off, 100[H], 200[H], 500[H], 1000[H] |
|
| Search mode |
|
| This feature sets the Auto Adjust mode. |
|
|
|
| Range: Normal, Fine |
| |
|
|
|
|
|