VIVOTEK

Content-Type: text/plain\r\n

Content-Length: 7\r\n \r\n

do1=1\r\n

8.4 3D Privacy Mask

Note: This request requires admin user privilege

<SD81X1> You can set privacy mask only at zoom 1x. To go back to zoom 1x directly, please send this cgi command: "/cgi-bin/camctrl/camposition.cgi?setzoom=0"

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/admin/setpm3d.cgi?method=<value>&name=<value>&[maskheight=<v alue>&maskwidth=<value>&return=<return page>]

PARAMETER

 

VALUE

 

DESCRIPTION

 

method

 

add

 

Add a 3D privacy mask at current location

 

 

 

 

 

 

 

 

 

delete

 

Delete a 3D privacy mask

 

 

 

 

 

 

 

 

 

edit

 

Edit a 3D privacy mask

 

 

 

 

 

 

 

maskname

 

string[40]

 

3D privacy mask name

 

 

 

 

 

 

 

maskheight

 

integer

 

3D privacy mask height

 

 

 

 

 

 

 

maskwidth

 

integer

 

3D privacy mask width

 

 

 

 

 

 

 

return

 

<return page>

 

Redirect to page <return page> after the 3D privacy

 

 

 

 

 

mask is configured. The <return page> can be a full

 

 

 

 

 

URL path or relative path according to the current path.

 

 

 

 

 

If you omit this parameter, it will redirect to an empty

 

 

 

 

 

page.

 

 

 

 

 

 

 

160 - User's Manual

60

 

 

Page 160
Image 160
Vivotek CC8130 user manual 3D Privacy Mask