VIVOTEK

7.24 UART control

Group: uart (capability.nuart > 0)

 

NAME

 

 

VALUE

 

 

DEFAULT

 

 

 

 

SECURITY

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

ptzdrivers_i<0~19,

 

 

string[40]

 

 

<product

 

 

1/4

 

 

Name of the PTZ driver.

 

127>_name

 

 

 

 

 

dependent>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ptzdrivers_i<0~19,

 

 

string[128]

 

 

< product

 

 

1/4

 

 

Full path of the PTZ driver.

 

127>_location

 

 

 

 

 

dependent >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

enablehttptunnel

 

 

<boolean>

 

0

 

 

 

4/4

 

 

Enable HTTP tunnel channel to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

control UART.

 

 

 

 

 

 

 

 

 

 

 

Group: uart_i<0~(n-1)>n is uart port count (capability.nuart > 0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NAME

 

 

VALUE

 

 

DEFAULT

 

 

 

 

SECURITY

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

baudrate

 

110,300,600,120

 

9600

 

 

4/4

 

 

Set baud rate of COM port.

 

 

 

0,2400,3600,480

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0,7200,9600,192

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00,38400,57600,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

databit

 

5,6,7,8

 

8

 

 

4/4

 

 

Data bits in a character frame.

 

 

 

6,7,8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<product

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dependent>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

paritybit

 

 

none,

 

 

none

 

4/4

 

 

For error checking.

 

 

 

 

odd,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

even

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stopbit

 

1,2

 

1

 

 

4/4

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1.5 , data bit is 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

uartmode

 

rs485,

 

 

rs485

 

4/4

 

 

RS485 or RS232.

 

 

 

 

rs232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

customdrvcmd_i<0~

 

 

string[128]

 

 

<blank>

 

1/4

 

 

PTZ command for custom

9>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

camera.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

speedlink_i<0~4>_n

 

 

string[40]

 

 

<blank>

 

1/4

 

 

Additional PTZ command name.

 

ame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

speedlink_i<0~4>_c

 

 

string[128]

 

 

<blank>

 

1/4

 

Additional PTZ command list.

 

md

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ptzdriver

 

0~19,

 

128

 

 

4/4

 

 

The PTZ driver is used by this

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

172 - User's Manual

Page 172
Image 172
Vivotek FE8174V user manual Uart control