state after duration.

it cannot accept new requests.

 

 

 

 

 

 

 

 

return

 

<return page>

Redirect to the page <return page> after the request is

 

 

 

 

 

completely assigned. The <return page> can be a full

 

 

 

 

 

URL path or relative path according the current path. If

 

 

 

 

 

you omit this parameter, it will redirect to an empty

 

 

 

 

 

page.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return Code

 

 

Description

 

 

200

 

 

The request is successfully executed.

400The request cannot be assigned, ex. incorrect parameters. Examples: setvi.cgi?vi0=0(10000)1(15000)0(20000)1

No multiple duration. setvi.cgi?vi3=0

VI index is out of range. setvi.cgi?vi=1

No VI index is specified.

503The resource is unavailable, ex. Virtual input is waiting for next state. Examples:

setvi.cgi?vi0=0(15000)1 setvi.cgi?vi0=1

Request 2 will not be accepted during the execution time(15 seconds).

8.24 Open Timeshift Stream (capability.timeshift > 0, timeshift_enable=1, timeshift_c<n>_s<m>_allow=1)

Note: This request requires Viewer access privileges.

Syntax:

For HTTP push server (MJPEG):

http://<servername>/<network_http_s<m>_accessname>?maxsft=<value>[&tsmode=<value>&reftime =<value>&forcechk&minsft=<value>]

For RTSP (MP4 and H264), the user needs to input the URL below into an RTSP compatible player.

rtsp://<servername>/<network_rtsp_s<m>_accessname>?maxsft=<value>[&tsmode=<value>&reftime =<value>&forcechk&minsft=<value>]