Vivotek IP7142 manual Drive the digital output, Query status of the digital input

Models: IP7142

1 95
Download 95 pages 56.23 Kb
Page 86
Image 86

VIVOTEK - A Leading Provider of Multimedia Communication Solutions

Drive the digital output

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>][&do3=<state>][&do4=<state>] [&return=<return page>]

Where state is 0, 1. “0” means inactive or normal state while “1” means active or triggered state.

Parameter

Value

Description

do<num>

0,

0

=> inactive, normal state

1

1

=> active, triggered state

 

 

 

Redirect to the page <return page> after the parameter

return

<return page>

is assigned. The <return page> can be a full URL path or

relative path according the current path. If you omit this

 

 

 

 

parameter, it will redirect to an empty page.

Example: Drive the digital output 1 to triggered state and redirect to an empty page

http://myserver/cgi-bin/dido/setdo.cgi?do1=1

Query status of the digital input

Note: This request requires the privilege of viewer.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]

If no parameter is specified, all the status of digital input will be returned.

Return:

HTTP/1.0 200 OK\r\n Content-Type: text/plain\r\n Content-Length: <length>\r\n \r\n

[di0=<state>]\r\n

[di1=<state>]\r\n

[di2=<state>]\r\n

[di3=<state>]\r\n

where <state> can be 0 or 1.

Example: Query the status of digital input 1

86 - User's Manual

Page 86
Image 86
Vivotek IP7142 manual Drive the digital output, Query status of the digital input