Vornado Ultrasonic Vortex Humidifier Operating Tips and Recommendations, Troubleshooting, Storage

Models: Ultrasonic Vortex Humidifier ULTRA1

1 21
Download 21 pages 10.73 Kb
Page 7
Image 7
Operating Tips and Recommendations

Operating Tips and Recommendations

Troubleshooting

For best results:

1.Allow for optimum airflow by keeping the mist outlet and grill un- obstructed. Ensure curtains and other items are far enough away from the unit to not be pulled into the side inlets or interfere with airflow.

2.Operate your Humidifier continuously. This will help maintain the desired humidity level in your home, cost only pennies a day, and will not damage the unit.

†It is normal and expected for your Humidifier to run continuously for a few days in order to raise the moisture content of the air to the desired level upon initial use or if the air is extremely dry. When your home and its furnishings have absorbed sufficient moisture and become stabilized at the desired humidity level, the amount of water used will decrease.

†If you operate your Humidifier continuously, it may need to be refilled with water every day. Simply look through the Water Tank to be certain that there is adequate water supply for operation. When the water level drops below the operating level, the misting function will stop.

†Any additives such as aroma fragrances or water conditioners must not be used. Any use of such additives will void the manufacturer’s warranty. These additives can cause cracks in the plastic of the Humidifier and may affect Transducer performance. Protect the Water Tank from damage. Any cracks or damage to the Tank may cause it to leak water onto the floor or other surfaces.

†If the Humidifier is turned Off, with water in the unit, and not turned back on for 12 hours or longer, or if the unit is not cleaned as recommended, you may experience some growth of algae or bacteria. These microorganisms may become airborne. Thoroughly clean the unit to eliminate any microorganisms (See CLEANING

12English

AND MAINTENANCE for instructions).

†Your Ultrasonic Vortex Humidifier is effective at supplying necessary moisture to dry air. It should be used with proper care to prevent over-humidification. To know if the humidity level is too high, gauge the condensation or frost on windows. Adjust your Humidifier to a point where this condition is at a minimum.

Storage

1.Thoroughly clean unit (See CLEANING INSTRUCTIONS).

2.Remove and discard Mineral Cartridge (See MINERAL CARTRIDGE REPLACEMENT). Be sure to buy a new Mineral Cartridge now so you are ready for next season!

3.Empty Water Tank and Base. Let unit dry completely.

4.Place in original retail carton if available.

5.Your Humidifier is now ready for Storage. Store in a cool, dry

location.

Note: It is recommended to clean the unit again before use.

Automatic Refill Program

Select the shipment interval and Vornado will send replacement Mineral Cartridges automati- cally. Eliminate the hassle of remembering to reorder. Maintain the high efficiency of your Vornado Humidifier.

To sign up, visit www.vornado.com, email con-

 

sumerservice@vornado.com or call 1-800-234-

 

0604. Cancel at anytime.

Part # MD1-0021

Problem

 

Possible Cause and Solution

 

 

 

 

 

 

Unit fails to power on.

 

 

Unit is not plugged in. Plug power cord into electrical outlet.

 

 

 

 

 

 

 

 

 

 

Household circuit breaker / ground fault interrupter has tripped or blown a fuse. Reset circuit breaker /

 

 

 

ground fault interrupter, or replace fuse. For assistance, contact a licensed electrician.

 

 

 

 

 

 

 

 

 

The unit has blown a fuse. Cease usage and unplug. Contact Consumer Service for assistance.

 

 

 

 

 

 

 

 

Unit is damaged or in need of repair. Cease usage and unplug. Contact Consumer Service for assistance.

 

 

 

 

 

Unit makes a bubbling or

 

 

This is normal. Water is being dispensed into Base.

 

gurgling sound.

 

 

 

 

 

 

 

 

Unit is not producing de-

 

 

Water level in Tank is empty or too low. Refill with clean, cool tap water. (See FILLING WATER TANK for

sired amount of humidity

 

 

instructions.)

 

or mist output has ceased.

 

 

 

 

 

 

Unit has reached its set point. When set humidity level is reached, the unit will not produce mist until humidity

 

 

 

 

 

 

level in the room drops below humidity set point.

 

 

 

 

 

 

 

 

 

Airflow is blocked. Remove obstruction.

 

 

 

 

 

 

 

 

Unit settings are too low. Set to High Output and Continuous Humidity for maximum humidity output.

 

 

 

 

White dust has accumu-

 

 

Mineral Cartridge is no longer removing minerals from water. Cartridge needs to be replaced (See MINERAL

lated on Mist Outlet or on

 

 

CARTRIDGE REPLACEMENT for instructions.)

 

flooring below.

 

 

 

 

 

 

Unit and Transducer is in need of cleaning. (See CLEANING AND MAINTENANCE for instructions.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Water is too hard. Use distilled water.

English 13

Page 7
Image 7
Vornado Ultrasonic Vortex Humidifier, ULTRA1 manual Operating Tips and Recommendations, Troubleshooting, Storage