Troubleshooting Chart:

GRDF / GRCF SERIES GAS FRYERS

OPEN PROBE – If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The digital control displays the following message:

“D” Solid State – OPEN PROBE

“C” Computer – PROBE OPEN

SHORTED PROBE – If a shorted probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The digital control displays the following message:

“D” Solid State – SHORTED PROBE

“C” Computer – PROBE SHORT

Hi TEMPERATURE – If the temperature is greater than or equal to 415°F (212°C), the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

“D” Solid State – HIGH TEMP

“C” Computer – HIGH TMP HIGH TMP

 

Troubleshooting Chart:

 

 

 

 

 

 

Problem:

 

Probable Cause:

 

 

 

No Heat:

 

Power switch not turned on.

 

 

Gas supply not turned on.

 

 

Wire connections loose (call service)

 

 

Wires connections need cleaning

 

 

High Limit (call service)

 

 

 

Insufficient or too much heat:

 

Temperature not set to desired temperature.

 

 

High limit tripped (call service)

 

 

Temperature probe (call service)

 

 

 

Tank will not drain:

 

Shortening too cold.

 

 

Drain pipe clogged with debris.

 

 

 

Motor / pump will not pump oil:

 

Suction tube not seated correctly in receptacle block.

 

 

Filter screen is clogged and needs cleaning.

 

 

Shortening is too thick / cold. Heat oil up to min. 300º F.

 

 

Discard valve lever not fully engaged either for filtering or

 

 

discarding.

 

 

 

 

 

 