Vulcan-Hart Troubleshooting Guide, Symptom, Cause, Remedy, Pilot does not light after

Models: 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72

1 20
Download 20 pages 57.26 Kb
Page 19
Image 19
Pilot does not light after

TROUBLESHOOTING GUIDE

SYMPTOM

CAUSE

REMEDY

 

Pilot does not light after

Problem with pilot valve

Check operation of pilot valve

 

igniter has been on

 

 

 

several minutes

Gas supply not purged of air

Purge gas lines

 

 

No gas supply

Check that gas supply is on

 

 

Loose wire connection

Check and repair wire connection

 

 

Obstructed or wrong size pilot orifice

Check for obstruction or wrong size

 

 

 

orifice

 

 

Problem with alignment of pilot and

Realign pilot and igniter

 

 

igniter

 

 

 

 

 

 

Pilot fails to remain lit

Loose wire connection

Check and repair wire connection

 

after igniter goes out

 

 

 

(Pilot may cycle on and

Air blowing pilot out

Correct air flow

 

off normally several times

 

 

 

after cold start-up before

Obstructed or wrong size pilot orifice

Check for obstruction or wrong size

 

the pilot heats up.)

 

orifice

 

 

Problem with alignment of pilot and

Realign pilot and igniter

 

 

flame switch

 

 

 

Problem with flame switch

Check operation of flame switch

 

 

 

 

 

Burner does not come on

Thermostat setting too low

Adjust thermostat to a high

 

(burner light does not

 

temperature setting

 

come on)

Problem with thermostat sensor

Replace sensor

 

 

 

 

Problem with temperature controller

Check or replace controller

 

 

Problem with thermostat gas valve

Check thermostat gas valve

 

 

Loose wire connection

Check and repair wire connection

 

 

 

 

 

Heat does not turn off,

Problem with thermostat gas valve

Check or replace thermostat gas

 

burner light is off,

 

valve

 

temperature is above

 

 

 

thermostat setting

 

 

 

 

 

 

 

Heat does not turn off,

Problem with temperature controller

Check or replace temperature

 

burner light is on,

 

controller

 

temperature is above

 

 

 

thermostat setting

 

 

 

 

 

 

 

Temperature varies

Low gas pressure

Check and adjust proper gas

 

 

 

pressure

 

 

Faulty thermostat sensor

Replace faulty thermostat and sensor

 

 

 

 

 

— 19 —

F35628 (10-04)

Page 19
Image 19
Vulcan-Hart service manual Troubleshooting Guide, Symptom, Cause, Remedy, Pilot does not light after