Vulcan-Hart ML-114826, VETRS35 Installation Codes And Standards, In the United States of America

Models: VETRS35 ML-114826

1 8
Download 8 pages 62.67 Kb
Page 4
Image 4
INSTALLATION CODES AND STANDARDS

INSTALLATION CODES AND STANDARDS

The tilting skillet must be installed in accordance with:

In the United States of America:

1.State and local codes.

2.National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1.Local codes.

2.Canadian Electrical Code, Part 2, CSA Standard C22.1 (latest edition). Copies may be obtained from The Canadian Standard Association, 178 Rexdale Blvd., Rexdale, Ontario, Canada M9W1R3.

LEVELING AND ANCHORING TILTING SKILLET

The tilting skillet must be anchored to the floor.

1.Place skillet in the installation position.

2.Place a carpenter's level on top of the skillet and turn the adjustable feet to level the skillet side to side and front to back.

3.Mark hole locations on the floor through the anchoring holes provided in the rear flanged adjustable feet. See diagram on page 5.

4.Remove skillet from installation position and drill holes in locations marked on the floor. Insert proper anchoring devices (not supplied).

5.Place skillet back in the installation position.

6.Place carpenter's level on top of skillet and re-level side to side and front to back.

7.Bolt and anchor skillet securely to the floor.

8.Seal bolts and flanged feet with a silicone or equivalent compound.

ELECTRICAL CONNECTIONS

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE YOU ARE WORKING ON THE CIRCUIT.

The control box for field wire connection is located at the left side rear when viewed from the front. A knockout hole is provided for a 12332" (43.6mm) conduit connection.

— 4 —

Page 4
Image 4
Vulcan-Hart ML-114826 Installation Codes And Standards, In the United States of America, In Canada, Electrical Connections