Vulcan-Hart VETRS35 Electrical Data, Service Connections, Model, Phase, 240V, 480V, KW Amp

Models: VETRS35 ML-114826

1 8
Download 8 pages 62.67 Kb
Page 5
Image 5
ELECTRICAL DATA

1.Remove the control box cover plate. Mount suitable 12332" (43.6mm) conduit fitting in knockout opening.

2.Connect field wire to the terminal block as indicated on the wiring diagram. The wiring diagram is located inside the wiring compartment at the rear of the tilting skillet. Wire must be of the type suitable for 90°C service.

3.After making the connections, replace the control box cover plate.

4.The tilting skillet must be grounded by installing a ground lead to the ground lug located inside the junction box.

ELECTRICAL DATA

Model

Phase

208V

240V

480V

 

 

 

KW Amp

KW Amp KW

Amp

VETRS35

3

18

50.0

18

43.3

18

21.6

SERVICE CONNECTIONS

— 5 —

Page 5
Image 5
Vulcan-Hart VETRS35, ML-114826 Electrical Data, Service Connections, Model, Phase, 240V, 480V, KW Amp KW