HEATING ELEMENT MOUNTING

VHX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS

HEATING ELEMENT MOUNTING

PLATE

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

1.Remove heating elements as outlined under

HEATING ELEMENTS.

2.Loosen mounting hardware securing control panel to frame and lower the panel.

3.On models with cooking compartments only, disconnect power cord from power switch box (rear of control panel).

4.Disconnect pressure gauge tube from fitting at tee.

5.Disconnect lead wire from Aux LLCO probe.

6.Loosen both conduit locking nuts (1 1/2" & 3/8") in main control box.

7.Loosen conduit nut (1 1/2") on elbow connected to main control box.

8.Remove mounting bolts for main control box.

A.Lift main control box to remove from the frame and position it to the left side.

9.Remove heating element mounting plate.

10.To install:

A.Clean the mating surfaces on heating element mounting plate and boiler.

B.Install new gasket on boiler side of mounting flange.