REMOVAL AND REPLACEMENT OF PARTS

VHX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS

REMOVAL AND REPLACEMENT OF PARTS

PRESSURE SWITCH CONTROL

BOX COMPONENTS

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

CAUTION: Certain components in this system are subject to damage by electrostatic discharge during field repairs. A field service grounding kit is available to prevent damage. The field service grounding kit must be used anytime a control board is handled.

1.Open the cabinet base door.

2.Remove cover from pressure switch control box.

3.Disconnect lead wires from component being replaced.

4.To remove:

A. Cycling pressure switch.

1)Disconnect compression fittings in the pressure supply line leading to the switch.

2)Remove mounting nuts from pressure switch mounting panel.

3)Disconnect conduit from box.