VHX SERIES STEAMER - ELECTRICAL OPERATION

1)Compartment steam solenoid valve energized and steam begins to enter the compartment.

2)Ready light (green) goes out and Cooking light (red) comes on.

NOTE: Steam should not be seen entering either compartment until a cook time is set. This energizes the steam solenoid valve of the cooking compartment to allow steam flow.

4.Time expires on timer.

A.Timer contacts 1/3 open, timer motor de- energized.

B.Steam solenoid valve de-energizes, stopping the flow steam into compartment.

C.Timer contacts 4/1 close and energize buzzer until manually turned off.

D.Cooking light (red) goes out and Ready light (green) comes on.

5.Timer manually turned off.

A.Contacts 1/4 open.

B.Alarm Buzzer de-energized and stops buzzing.

6.Steamer reverts to preheat cycle until time is dialed on timer and the door is shut, water level drops below low level cut-off probe or the power switch is turned off.