VHX SERIES STEAMER - ELECTRICAL OPERATION
1)Compartment steam solenoid valve energized and steam begins to enter the compartment.
2)Ready light (green) goes out and Cooking light (red) comes on.
NOTE: Steam should not be seen entering either compartment until a cook time is set. This energizes the steam solenoid valve of the cooking compartment to allow steam flow.
4.Time expires on timer.
A.Timer contacts 1/3 open, timer motor de- energized.
B.Steam solenoid valve
C.Timer contacts 4/1 close and energize buzzer until manually turned off.
D.Cooking light (red) goes out and Ready light (green) comes on.
5.Timer manually turned off.
A.Contacts 1/4 open.
B.Alarm Buzzer
6.Steamer reverts to preheat cycle until time is dialed on timer and the door is shut, water level drops below low level