C24GA SERIES GAS CONVECTION STEAMERS
In Canada:
1.Local codes.
2.
3.
LOCATION - GAS STEAMERS
The equipment area must be kept free and clear of combustible substances.
The recommended clearance for proper operation is 36" (914 mm) at the front. The required clearance from combustible or non- combustible construction is 0" at the sides and back. The recommended clearance for service access is 18" (457 mm) at the sides and 6" (152 mm) from the back.
Make sure there is an adequate supply of air in the room to replace air taken out by the ventilating system. If you have any questions, contact the ventilation system installer.
An exhaust system should be located directly above the steamer to exhaust steam, flue exhaust and heat generated by the steamer.
Do not locate the steamer directly over a drain.
LEVELING AND ANCHORING
Position the steamer in its final installed location. Place a level on the horizontal area of the cabinet. Adjust the feet to level the steamer in both the
Steamers should be elevated in the front just enough, about 1/16" to 1/8" (2 to 3mm) to give proper draining. Do this by rotating the adjustable feet in the proper direction 1 to 1½ turns after leveling. Check drainage in the steamer compartments by pouring a small amount of water in the compartment. All the water should drain.
The rear feet have holes in the flanges for anchor bolts.
— 4 —