Installation, Operation and Care Of
MODEL GH SERIES HEAVY-DUTY GAS RANGES
SAVE THESE INSTRUCTIONS
GENERAL
Vulcan ranges and ovens are produced with quality workmanship and material. Proper installation, usage and maintenance of your range will result in many years of satisfactory performance.
The manufacturer suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided.
INSTALLATION
UNPACKING
This range was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for possible shipping damage. If the range is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
Carefully unpack range(s) and place in the approximate installation position, whether as a battery or single
Before installing, check the electrical service (Convection Oven Models only) and type of gas supply (natural or propane) to make sure they agree with the specifications on the rating plate located on the lower
LOCATION
CAUTION: The equipment area must be kept free and clear of combustible substances.
The following ranges, when installed, must have a minimum clearance from combustible construction of 6" (152 mm) at the sides and 6" (152 mm) at the rear. Clearance from noncombustible construction can be 0" (0 mm) at the sides and rear:
GH30 | GH6C | GH60TS | GH60/45 | GHX60 |
GH30C | GH6S | GH72 | GH60/45C | GHX60T |
GH30S | GH60 | GH72C | GH60/45S | GHX72 |
GH45 | GH60C | GH72S | GH60T45 |
|
GH45C | GH60S | GH72/45 | GH60T45C |
|
GH45S | GH60T | GH72/45C | GH60T45S |
|
GH6 | GH60TC | GH72/45S | GHX45 |
|
– 4 –