Vulcan-Hart VRT32I ML-138024 operation manual Electrical Requirements, Electrical Connections

Models: VRT32I ML-138024

1 19
Download 19 pages 2.24 Kb
Page 5
Image 5

VCH & VRT SERIES OVENS

F-38055 (11-09)

ELECTRICAL REQUIREMENTS

diagrams and Specification Chart in the back of this manual.

ELECTRICAL CODES & STANDARDS:

The oven must be installed in accordance with:

In the United States of America:

1.State and Local Codes.

2.National Electrical Code, ANSI/ NFPA-70 (latest edition.) Copies may be obtained from: The

National Fire Protection Association, 1Batterymarch Park, Quincy, MA 02269.

1-617-770-3000 www.nfpa.org

In Canada:

1.Local Codes.

2.Canadian Electrical Code, CSA C22.1 (latest edition.) Copies may be obtained from: The Canadian Standard Association. www.csa.ca

ELECTRICAL CONNECTIONS:

The oven is factory wired for either 110/120 volt single phase or 208/240 volt three phase operation. All 110/120 volt cabinets are equipped with an 8 foot cord and NEMA 5-15 plug as standard equipment. All 208/240 volt cabinets are equipped with an 8 foot cord and NEMA 6-15 plug. Refer to wiring

Page 4

The cord and plug supplied is a suitable durable cord with a proper strain relief.

WARNING: All 110/120 volt ovens are equipped with a three-prong plug. It is imperative that this plug must be connected into a properly grounded

three-prong receptacle. If the receptacle is not the proper grounding type, contact an electrician. DO NOT REMOVE THE GROUNDING PRONG FROM THIS PLUG.

CAUTION: Verify that the power source matches the Serial Data Plate located on the lower back corner of the oven and the plug configuration before the connection is made. (Fig.1)