VXI CT-100B user manual Rack Mount Door Kit Installation, Required Tools, Parts List, Vti P/N

Models: CT-100B

1 33
Download 33 pages 13.61 Kb
Page 26
Image 26
RACK MOUNT DOOR KIT INSTALLATION

VXI Technology, Inc.

RACK MOUNT DOOR KIT INSTALLATION

The rack mount door kit (Option 60) provides the necessary hardware to install a 1/8” thick aluminum door in front of the rack mounted chassis. This option requires that the rack mount ear kit also be installed and configured for recessed mounting. The door may be customer modified to hold connectors, controls, indicators and similar components.

REQUIRED TOOLS

1.#2 Phillips Screwdriver

2.1/8" Flat Blade Screwdriver

3.11/32" Open Ended Wrench

PARTS LIST

QTY

ITEM

VTI P/N

2

Slide, Rack Mount, Steel, 20"

37-0054-020

1

Hardware Kit, Rack Mount Slide, Steel

37-0055-000

6

Screw, 8-32 x 3/8" Pan Head Phillips, Sems Zinc

37-0073-037

6

Screw, 8-32 x 1/4" Pan Head Phillips, Steel/Zinc

37-0074-025

4

Screw, 8-32 x 3/8", F/H Undercut Phillips, Zinc

37-0115-037

2

Bracket, Slide, Front, 5 Slot Chassis, CT-100B

41-0108-000

1

Bracket, Slide, Top Side, CT-100B

41-0131-000

1

Bracket, Slide, Bottom, CT-100B

41-0132-000

ASSEMBLY PROCEDURE

1.Lay the chassis on a protected work surface on its long side with the voltage monitor LEDs of the chassis facing front with the power switch toward the top.

2.Locate two rackmount (cross) braces. Install one each along the front of the flanges (one on top and one on the bottom) using four (two ea.) #8 flathead screws. The lip along the long edge of each brace goes toward the front and pointing inside. The braces fit over the flanges and the screws are placed from the inside going through the flange and then into the brace.

3.Locate the front door and two hinges. Install the two hinges to the front door using four black screws provided.

4.Locate the latch kit and install it into the door from the side where the hinges are mounted.

5.Locate the door latch bracket and install it on the rack mount ear opposite the end where the hinges will be installed. Use the rack mount door installation diagram below as a reference.

6.Locate the four tapped holes on the front surface of the rack mount ear to which the door is to be attached.

7.Install the door by its hinges to the rack mount ear using four black screws provided with the option kit.

8.Test that the door opens and closes smoothly and adjust the latch as necessary to secure the door when latched close.