www.vxitech.com

POWER SPECIFICATIONS

USEABLE POWER

450 W at 40°C

DC Supply Voltage

Voltage

Peak Current (IMP)

Dynamic Current (IMD)

+5 V

35 A

5 A

-5.2 V

25 A

4 A

-2 V

7 A

2 A

+12 V

4 A

2 A

-12 V

4 A

1.5 A

+24 V

4 A

3 A

-24 V

4 A

3 A

 

 

 

Output Voltage

 

 

 

Voltage

 

 

Allowed Variation

 

 

Ripple/Noise

 

 

Induced Ripple

 

 

 

 

 

 

 

 

 

DC Load

 

 

Noise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+5 V

 

+0.25 V / -0.125 V

 

 

50 mV

 

 

50 mV

 

 

 

 

 

-5.2 V

 

-0.26 V / +0.125 V

 

 

50 mV

 

 

50 mV

 

 

 

 

 

-2 V

 

-0.10 V / +0.72 V

 

 

50 mV

 

 

50 mV

 

 

 

 

 

+12 V

 

+0.60 V / +0.36 V

 

 

50 mV

 

 

50 mV

 

 

 

 

 

-12 V

 

-0.60 V / +0.36 V

 

 

50 mV

 

 

50 mV

 

 

 

 

 

+24 V

 

+1.20 V / -0.72 V

 

 

150 mV

 

 

150 mV

 

 

 

 

 

-24 V

 

-1.20 V / +0.74 V

 

 

150 mV

 

 

150 mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Voltage

115 VAC, nominal 90 – 132 VAC

 

 

 

 

 

 

 

 

AC

 

 

 

 

 

 

 

 

 

230 VAC, Nominal 180 – 264 VAC}Auto Selected

 

 

 

 

 

Frequency

47 Hz – 63 Hz

 

 

 

 

 

 

 

 

 

Fuse

10 A slow blow

 

 

 

 

 

 

 

 

 

115 V Operation

 

 

 

 

 

 

 

 

 

220 V Operation

5 A slow blow

 

 

 

 

 

 

 

 

 

+5VSTBY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 A max, user supplied

Standard banana jack on rear panel, voltage and ground

POWER SUPPLIES (TBD)

UL, CSA, TUV approved

Shout circuit, over-voltage, reverse voltage and thermal shutdown protection

CT-100B Installation

15

Page 15
Image 15
VXI Six-Slot VXIBus Chassis, CT-100B user manual +5VSTBY