Waterford Appliances E61-LP, E61-NG Safety Label, Listed VENT GAS FIREPLACE HEATER

Models: E61-LP E61-NG

1 24
Download 24 pages 7.21 Kb
Page 5
Image 5
Listed: VENT GAS FIREPLACE HEATER

Waterford E61 Gas Fireplace Insert

NOTE: Waterford units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

This is a copy of the label that accompanies each Waterford E61-LP Gas Insert Propane. We have printed a copy of the contents here for your review. The safety label is located on the right side door panel.

 

 

 

 

 

 

DUPLICATE SERIAL NO.

204

 

Listed: VENT GAS FIREPLACE HEATER

 

 

 

 

 

 

 

DO NOT REMOVE OR COVER THIS LABEL /

 

 

 

Certified for/Certifiée pour: CANADA and U.S.A.

 

 

 

NE PAS ENLEVER CETTE ÉTIQUETTE

 

 

 

 

 

 

 

 

Report No. 476-1714-00 (Oct. 1999)

 

 

 

 

Serial no./

 

 

 

 

 

204

 

Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003, CAN/CGA 2.17-M91

 

 

 

 

 

No de serie

 

 

 

 

 

 

 

 

 

 

FACTORY EQUIPPED FOR PROPANE

Model:E61LP ÉQUIPÉ A L'UISINE POUR GAZ PROPANE

Minimum supply pressure 12" WC/C.E. (3.00 kPa)

Pression d'allimentation minimum

Manifold pressure High

11" WC/C.E.

(2.74 kPa)

Pression à la tubulure d'échappement élevée

Manifold pressure Low

2.9" WC/C.E. (0.72 kPa)

Pression à la tubulure d'échappement basse

Factory Equipped for 35,000 Btu

 

 

 

Maximum Input

35,000

Btu/h (10.26 Kw/h)

Débit Calorifique maximum

Minimum Input

17,500

Btu/h (5.13 Kw/h)

Débit Calorifique minimum

Orifice size

#50 DMS

 

(1.8mm)

Dimensions de l'orifice

Altitude

0-2000 ft/pi

(0-610m)

L'altitude

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.

FOR USE WITH GLASS DOORS CERTIFIED WITH

APPLIANCE ONLY.

This vented gas fireplace heater is not for

use with air filters.

Not for use with solid fuel.

Electrical Supply (115 V, 1.13A, 60 Hz)

Approved for use with Emerald Zero Clearance Kit, Part No. 270-900.

5

Convertible to 29,000 Btu for Altitude 0 - 4500 ft. with Kit #: 260-922

Maximum Input

29,000 Btu/h (8.50 Kw/h)

Débit Calorifique maximum

Minimum Input

14,500 Btu/h (4.25 Kw/h)

Débit Calorifique minimum

Orifice size

#52 DMS

(1.61mm)

Dimensions de l'orifice

Altitude

0-4500 ft/pi

(0-1372m)

L'altitude

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanenlty located,manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.

Made in Canada/ Fabrique au Canada

FPI Fireplace Products International Ltd., Delta, BC, Canada

908-438b

 

Minimum Clearances

 

to Combustibles/

 

Degagement Minimum

B

De Materiaux Combustibles

Unit to Sidewalls

A 9"/230mm

 

 

Top of Hob to mantel:

A

unshielded

B 16"/406mm

 

shielded

B 12"/305mm

 

To ceiling fromtop of stove: 36"/ 915mm

Floor Protector

A floor protector consisting of one layer of ½" thick WonderBoardCertified for/Certifiée pour: CANADA and U.S.A., DurockReport No. 476-1714-00 (Oct. 1999), or equivalent extending at least 9" in front of the face of the unit and the full width of the front surface is required.

SAFETY LABEL

Page 5
Image 5
Waterford Appliances E61-LP Safety Label, Listed VENT GAS FIREPLACE HEATER, Certified for/Certifiée pour CANADA and U.S.A