Operating Instructions

Lighting the Smoker Burner

1

 

WARNING: Check hose before each use of grill for

 

 

nicks, cracking, abrasions or cuts. If the hose is found

 

2,3,9

to be damaged in any way, do not use the grill.

 

 

 

Replace using only Weber® authorized replacement

 

 

hose Contact the Customer Service Representative in

 

 

your region using the contact information sheet

 

8

provided with your manual.

6

1)

Open the grill lid.

 

 

DANGER:

 

 

Failure to open the lid while igniting the grill, or not

4

5

waiting 5 minutes to allow the gas to clear if the grill

 

 

does not light, may result in an explosive flare-up

 

7

which can cause serious bodily injury or death.

 

 

2) Open smoker box lid

 

4

 

 

3) Fill smoker with water soaked wood chunks or chips.

*The grill illustrated may have slight differences than the

4) Make sure all burner control knobs are turned OFF.

model purchased.

(Push control knob down and turn clockwise to ensure

 

 

that it is in the OFF position.)

 

 

WARNING: The burner control knobs must be in the

5) Turn the cylinder on by turning the cylinder valve

OFF position before turning on the liquid propane

 

counterclockwise.

cylinder tank valve. If they are not in the OFF position,

 

 

WARNING: Do not lean over the open grill while

when you turn on the LP cylinder valve, the “excess

 

lighting.

gas flow control” feature will activate, limiting the flow

6) Push smoker burner control knob down and turn to

of gas from the LP cylinder. If this should occur, turn

 

START/HI.

OFF the LP cylinder valve and burner control knobs.

 

7) Push and hold down the Igniter button until burner

Then start over.

 

ignites. You will hear the igniter sparking.

 

 

DANGER:

8) Check that the burner is lit by looking through the

 

cooking grate.

When the “excess gas flow control” feature is

 

 

 

activated, a small amount of gas is still flowing to the

 

DANGER:

burners. After turning OFF the cylinder and burner

 

If the smoker burner does not light, turn the burner

control knobs, wait at least 5 minutes for the gas to

control knob to OFF and wait 5 minutes to let the gas

clear before attempting to light the grill. Failure to do

clear before you try again or try to light with a match.

so may result in an explosive flare-up, which can

 

 

cause serious bodily injury or death.

9)

Close smoker cover after wood starts to smolder and

 

 

turn control knob to LOW.

To Extinguish

Push down and turn each burner control knob clockwise to OFF position. Turn gas supply OFF at the source.

D-7

Page 40
Image 40
Weber 41995 manual Lighting the Smoker Burner